Comparison of fluoro and cine angiographic modes in coronary stenting procedure: A preliminary feasibility study

dc.authorid0000-0002-4607-5724
dc.authorid0000-0002-4281-0867
dc.authorid0000-0003-1919-3183
dc.authorid0000-0003-2542-3467
dc.contributor.authorOlcay, Ayhan
dc.contributor.authorGüler, Ekrem
dc.contributor.authorKaraca, İbrahim Oğuz
dc.contributor.authorKızılırmak, Filiz
dc.contributor.authorOlgun, Fatih Erkam
dc.contributor.authorYenipınar, Esra
dc.contributor.authorDuman, Dursun
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:56:33Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:56:33Z
dc.date.issued2014
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Kalp ve Damar Cerrahisi Ana Bilim Dalı
dc.descriptionWOS: 000345232200085
dc.descriptionPubMed ID: 25205486
dc.description.abstractX-ray exposure of patient during coronary angiography (CA) and percutaneous coronary intervention (PCI) may have some deleterious effects. The radiation dose per frame for digital acquisitions can be 15 times greater than that for fluoroscopy. The number and length of digital acquisition or cine “runs” may be the greatest source of patient radiation dose in interventional cardiology procedures. Last fluoroscopy hold (LFH) is a new advanced feature that dynamically stores only the last current sequence of fluoroscopy images for instant replay, editing and storage in radiography and fluoroscopy systems without the need for operator pre-setting. LFH could reduce the fluoroscopy time to half compared to when it is not used and enables the operator to examine the image as long as necessary for decision making without the use of radiation [1–7].
dc.identifier.citationOlcay, A., Güler, E., Karaca, İ. O., Kızılırmak, F., Olgun, F. E., Yenipınar, E. ... Duman, D. (2014). Comparison of fluoro and cine angiographic modes in coronary stenting procedure: A preliminary feasibility study. International Journal of Cardiology, 177(2), 595-596. https://dx.doi.org/10.1016/j.ijcard.2014.08.144
dc.identifier.doi10.1016/j.ijcard.2014.08.144
dc.identifier.endpage596
dc.identifier.issn0167-5273
dc.identifier.issn1874-1754
dc.identifier.issue2
dc.identifier.scopusqualityQ1
dc.identifier.startpage595
dc.identifier.urihttps://dx.doi.org/10.1016/j.ijcard.2014.08.144
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2741
dc.identifier.volume177
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofInternational Journal of Cardiologyen_US
dc.relation.publicationcategoryDiğer
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCoronary Angiography
dc.subjectRadiation
dc.subjectLast Fluoro Hold
dc.subjectStent
dc.titleComparison of fluoro and cine angiographic modes in coronary stenting procedure: A preliminary feasibility study
dc.typeLetter

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Guler, Ekrem-2014.pdf
Boyut:
150.18 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text