Er:YAG lazer ya da geleneksel yöntem ile hazırlanmış sınıf V kavitelerde akışkan kompozitlerin kenar uyumlarının araştırılması
| dc.authorid | 0000-0001-5489-6883 | |
| dc.contributor.author | Üstün, Nilüfer | |
| dc.contributor.author | Güven, Yeliz | |
| dc.contributor.author | Dinçer, Asiye Nur | |
| dc.contributor.author | Tuna İnce, Elif Bahar | |
| dc.contributor.author | Özel, Emre | |
| dc.date.accessioned | 2023-03-30T12:42:50Z | |
| dc.date.available | 2023-03-30T12:42:50Z | |
| dc.date.issued | 2021 | |
| dc.department | İstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Çocuk Diş Hekimliği Ana Bilim Dalı | |
| dc.description.abstract | Amaç: Bu çalışmanın amacı, Er:YAG lazer ya da yüksek hızlı döner aletler ile kavite hazırlığı yapılan ve üç farklı akışkan kompozit materyali kullanılarak gerçekleştirilen sınıf V restorasyonlarda kenar mikrosızıntılarının incelenmesidir. Gereç ve Yöntem: Bu in-vitro çalışmada, toplam 33 adet üçüncü büyük azı dişlerinin bukkal ve lingual yüzeylerinde Er:YAG lazer ya da frez kullanılarak sınıf V kaviteler hazırlanan örnekler altı gruba (n=11) ayrıldı ve üretici firmanın talimatlarına uygun olarak üç farklı akışkan kompozit ile restore edildi. Grup 1: Lazer ile hazırlık (lh)+Estelite Flow Quick High flow (EF); Grup 2: lh+G-aenial Flo (GF); Grup 3: lp+Herculite XRV Ultra Akış (HF); Grup 4: Frez ile hazırlık (fh)+EF; Grup 5: fh+GF; Grup 6: fh+HF. Isısal çevrim uygulanmasının ardından örnekler %0,5 metilen mavisi solüsyonunda 24 saat süresince bekletildi. Boya penetrasyonu sonucu oluşan mikrosızıntı, stereomikroskop altında x40 büyütme ile incelendi. Verilerin analizinde Kruskal Wallis ve Mann-Whitney U testleri kullanıldı (p<0,05). Bulgular: Grup 3’te oluşan mikrosızıntı düzeyi grup 2’ye göre istatistiksel açıdan anlamlı derecede düşük bulunurken (p:0,042), diğer gruplar arasındaki mikrosızıntı düzeylerinde anlamlı bir farklılık saptanmadı. Gruplardaki gingival ve oklüzal yüzeyler karşılaştırıldığında mikrosızıntı düzeyleri arasında istatistiksel olarak anlamlı bir farklılık bulunmadı (p<0,05). Sonuç: Sınıf V kavite hazırlığında yüksek hızlı döner alet ya da Er:YAG lazer uygulaması ve bu kavitelerin restorasyonlarında farklı akışkan kompozit materyallerinin kullanılması, oklüzal ve gingival kenarlarda oluşan mikrosızıntı düzeyini etkilememektedir. | |
| dc.description.abstract | Aim: The aim of this study was to examine the Er:YAG laser and high-speed bur cavity preparation on the marginal microleakage of class V cavities restored with three different flowable composites. Materials and Methods: This in-vitro study was conducted on class V cavities prepared on buccal and lingual surfaces of 33 third molar teeth in six groups (n=11) of Er:YAG laser and bur preparation. The cavities were restored with three different flowable composites according to the manufacturer’s instructions. Group 1: Laser preparation (lp)+Estelite Flow Quick High flow (EF); Group 2: lp+G-aenial Flo (GF); Group 3: lp+Herculite XRV Ultra Flow (HF); Group 4: Bur preparation (bp)+EF; Group 5: bp+GF; Group 6: bp+HF. After thermocycling, the teeth were immersed in 0.5% methylene blue dye for 24 hours. The teeth were examined under a stereomicroscope at ×40 magnification to detect the microleakage. Data were analyzed by Kruskal-Wallis and Mann Whitney U tests (p<0.05). Results: While the microleakage in group 3 was found significantly lower than group 2 (p:0.042), there was no significant difference among the other groups (p>0.05). In terms of gingival and occlusal surfaces, no statistically significant difference in microleakage was observed among all groups (p>0.05). Conclusion: Class V cavity preparations with high-speed bur and Er:YAG laser, and the use of different flowable composites did not influence the microleakage at the gingival or occlusal margins. | |
| dc.identifier.citation | Üstün, N., Güven, Y., Dinçer, A. N., Tuna İnce, E. B. ve Özel, E. (2021). Er:YAG lazer ya da geleneksel yöntem ile hazırlanmış sınıf V kavitelerde akışkan kompozitlerin kenar uyumlarının araştırılması. 7tepe Klinik, 17(1), 16-22. https://dx.doi.org/10.5505/yeditepe.2021.50469 | |
| dc.identifier.doi | 10.5505/yeditepe.2021.50469 | |
| dc.identifier.endpage | 22 | |
| dc.identifier.issn | 2458-9586 | |
| dc.identifier.issue | 1 | |
| dc.identifier.startpage | 16 | |
| dc.identifier.uri | https://dx.doi.org/10.5505/yeditepe.2021.50469 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12511/10773 | |
| dc.identifier.volume | 17 | |
| dc.indekslendigikaynak | TR-Dizin | |
| dc.institutionauthor | Üstün, Nilüfer | |
| dc.language.iso | tr | |
| dc.publisher | Yeditepe Üniversitesi Rektörlüğü | |
| dc.relation.ispartof | 7tepe Klinik | en_US |
| dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Mikrosızıntı | |
| dc.subject | Er:YAG Lazer | |
| dc.subject | Yüksek Hızlı Döner Alet | |
| dc.subject | Kavite Hazırlığı | |
| dc.subject | Akışkan Kompozitler | |
| dc.subject | Microleakage | |
| dc.subject | Er:YAG Laser | |
| dc.subject | High-Speed Bur | |
| dc.subject | Cavity Preparation | |
| dc.subject | Flowable Composites | |
| dc.title | Er:YAG lazer ya da geleneksel yöntem ile hazırlanmış sınıf V kavitelerde akışkan kompozitlerin kenar uyumlarının araştırılması | |
| dc.title.alternative | Assessment of the marginal microleakage of flowable composites in class V cavities prepared by Er:YAG laser and high-speed bur | |
| dc.type | Article |











