dc.description.abstractObjectives: The aim of this study was to evaluate dentin crack incidence after root canal instrumentation usingProTaper Next (PT Next; Dentsply Maillefer, Ballaigues, Switzerland) and Twisted File Adaptive (TF Adaptive;Sybron Endo, Orange, California, USA) at different kinematics.Methods: Sixty human extracted premolar teeth were selected and divided into 4 main groups. Group 1: PTNext with continuous rotation (n = 15); Group 2: PT Next with adaptive motion (n = 15); Group 3: TF Adaptivewith continuous rotation (n = 15); Group 4: TF Adaptive with adaptive motion (n = 15). Fifteen unpreparedteeth were used as control group. Crowns of the teeth were removed and roots were sectioned at 3, 6, and 9mm from the apex using a diamond saw. Finally root dentin pieces were evaluated under stereomicroscope atx25 magnification. Digital images were evaluated by 2 researchers.Results: No cracks were observed in the control group. In groups 2 and 4 no fracture was observed at the levelof 9 mm and similarly in group 4 at 6 mm level. Group 3 showed a significantly higher dentin crack formationfollowed by Group 1, 2, 4 and control group respectively (p < 0.039). There was no significant differencebetween groups at 6 mm and 9 mm levels (p = 0.497) except for only 3 mm level (p < 0.035).Conclusions: It was concluded, both adaptive motion and continuous rotationpromoted dentinal defect.Adaptive motion produced less dentinal defects all dentin levels but there was no significant difference.
dc.identifier.citationErkan, E., Olcay, K., Eyüboğlu, T. F. ve Gündoğar, M. (2019). Incidence of dentinal crack formation during root canal preparation with two NiTi instruments activated by adaptive motion and continuous rotation: An in vitro study. The European Research Journal, 5(5), 757-762. https://doi.org/10.18621/eurj.417982
dc.identifier.doi10.18621/eurj.417982
dc.identifier.endpage762
dc.identifier.issn2149-3189
dc.identifier.issue5
dc.identifier.startpage757
dc.identifier.urihttps://doi.org/10.18621/eurj.417982
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9241
dc.identifier.volume5
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorErkan, Erhan
dc.institutionauthorOlcay, Keziban
dc.institutionauthorEyüboğlu, Tan Fırat
dc.institutionauthorGündoğar, Mustafa
dc.language.isoen
dc.relation.ispartofThe European Research Journalen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectDentinal Crack
dc.subjectRoot Canal Preparation
dc.subjectProtaper Next
dc.subjectTwisted File Adaptive
dc.subjectNickel-Titanium Instruments
dc.subjectAdaptive Motion
dc.subjectContinuous Rotation
dc.titleIncidence of dentinal crack formation during root canal preparation with two NiTi instruments activated by adaptive motion and continuous rotation: An in vitro study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Erkan-Kezban-2019.pdf
Boyut:
303.38 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: