Near zero fluoroscopy radiation exposure during successful catheter ablation of atrial tachycardia from the non-coronary aortic cusp using 3-dimentional electroanatomic mapping system
| dc.authorid | 0000-0002-4607-5724 | |
| dc.authorid | 0000-0002-4281-0867 | |
| dc.authorid | 0000-0003-1919-3183 | |
| dc.contributor.author | Güler, Ekrem | |
| dc.contributor.author | Karaca, Oğuz | |
| dc.contributor.author | Kızılırmak, Filiz | |
| dc.contributor.author | Babür Güler, Gamze | |
| dc.contributor.author | Kılıçaslan, Fethi | |
| dc.date.accessioned | 10.07.201910:49:13 | |
| dc.date.accessioned | 2019-07-10T19:36:04Z | |
| dc.date.available | 10.07.201910:49:14 | |
| dc.date.available | 2019-07-10T19:36:04Z | |
| dc.date.issued | 2014 | |
| dc.department | İstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalı | |
| dc.description.abstract | Atrial tachycardia (AT) rarely originates from the paraHisian region (1). Catheter ablation of paraHisian AT carries a substantial risk of atrioventricular (AV) block. Cryoablation offers a safer ablation strategy for these patients (2). There is a small risk of AV block with cryoablation. Ablation of paraHisian AT from the non-coronary aortic cusp (NCC) is an option in these patients. We report a patient with paraHisian AT that was successfully ablated from the NCC by 3-Dimentional (3-D) mapping system with using near zero fluoroscopy (NZF). | |
| dc.identifier.citation | Güler, E., Karaca, O., Kızılırmak, F., Babür Güler, G. ve Kılıçaslan, F. (2014). Near zero fluoroscopy radiation exposure during successful catheter ablation of atrial tachycardia from the non-coronary aortic cusp using 3-dimentional electroanatomic mapping system. The Anatolian Journal of Cardiology, 14(6), 556-557. https://dx.doi.org/10.5152/akd.2014.5507 | |
| dc.identifier.doi | 10.5152/akd.2014.5507 | |
| dc.identifier.endpage | 557 | |
| dc.identifier.issn | 1302-8723 | |
| dc.identifier.issue | 6 | |
| dc.identifier.scopusquality | N/A | |
| dc.identifier.startpage | 556 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12511/1051 | |
| dc.identifier.uri | https://dx.doi.org/10.5152/akd.2014.5507 | |
| dc.identifier.volume | 14 | |
| dc.identifier.wosquality | Q4 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | TR-Dizin | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | AVES | |
| dc.relation.ispartof | The Anatolian Journal of Cardiology | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Near Zero Fluoroscopy Radiation Exposure | |
| dc.subject | Catheter Ablation | |
| dc.subject | Atrial Tachycardia | |
| dc.subject | Non-Coronary Aortic Cusp | |
| dc.subject | 3-Dimentional Electroanatomic Mapping System | |
| dc.title | Near zero fluoroscopy radiation exposure during successful catheter ablation of atrial tachycardia from the non-coronary aortic cusp using 3-dimentional electroanatomic mapping system | |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- guler-ekrem(2014).pdf
- Boyut:
- 82.94 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text











