Comparison of two digital intraoral radiography imaging systems as a function of contrast resolution and exposure time

dc.authorid0000-0002-6429-4197
dc.contributor.authorCesur Aydın, Kader
dc.contributor.authorDemirel, O?uzhan
dc.contributor.authorÖzcan, Mutlu
dc.date.accessioned2020-12-21T11:54:58Z
dc.date.available2020-12-21T11:54:58Z
dc.date.issued2020
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı
dc.description.abstractBackground: To compare the image quality of two different digital imaging systems; one photostimulable phosphor plate system (PSP) and a direct digital radiography system with CMOS imaging sensor; via evaluating contrast resolution among four different exposure times. Methods: Endodontically treated incisor teeth embedded in paraffin blocks are aligned next to a 99.5% Al wedge and exposed for 0.8, 0.1,0.125 and 0.16 seconds using both the CMOS and PSP systems. Using ImageJ software, 5 isometric and isogridded ROI from each root filling area and isometric ROI from the Al stepwedge were calculated. Results: Evaluation of the total of 120 images displayed that PSP system produced significantly higher contrast resolution (P<0.05) in regard to pixel values than the CMOS. The CMOS system was non- responsive to increasing dose (P=0.000). Regarding the EqAl values, no significant difference was determined between groups (P>0.05). Conclusions: The contrast resolution was higher using the PSP system. It can be estimated that, filling material will be more obvious under lower doses using PSP.
dc.identifier.citationCesur Aydın, K., Demirel, O. ve Özcan, M. (2020). Comparison of two digital intraoral radiography imaging systems as a function of contrast resolution and exposure time. Minerva Stomatologica, 69(3), 148-152. https://dx.doi.org/10.23736/S0026-4970.19.04286-9
dc.identifier.doi10.23736/S0026-4970.19.04286-9
dc.identifier.endpage152
dc.identifier.issn0026-4970
dc.identifier.issn1827-174X
dc.identifier.issue3
dc.identifier.scopusqualityQ3
dc.identifier.startpage148
dc.identifier.urihttps://dx.doi.org/10.23736/S0026-4970.19.04286-9
dc.identifier.urihttps://hdl.handle.net/20.500.12511/6119
dc.identifier.volume69
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherEdizioni Minerva Medica
dc.relation.ispartofMinerva Stomatologicaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectRadiography
dc.subjectDental
dc.subjectTechnology
dc.subjectRadiologic
dc.subjectDiagnostic Equipment
dc.titleComparison of two digital intraoral radiography imaging systems as a function of contrast resolution and exposure time
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Aydin, Kader-2020.pdf
Boyut:
462.03 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: