Evaluation of the relationship between placental thickness and obstetric doppler parameters during the second trimester

dc.authorid0000-0001-8877-2803
dc.contributor.authorAydın, Emine
dc.contributor.authorBulut, Ayça Nazlı
dc.date.accessioned2021-04-20T08:43:26Z
dc.date.available2021-04-20T08:43:26Z
dc.date.issued2020
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Kadın Hastalıkları ve Doğum Ana Bilim Dalı
dc.description.abstractOBJECTIVE: To determine whether there is a relationship between placental thickness and the umbilical artery and uterine artery Doppler evaluation in the second trimester. STUDY DESIGN: The placental thickness and the umbilical artery and uterine artery Doppler evaluations were recorded by a single operator for patients who were admitted for an obstetric follow-up or fetal anatomy screening at 18-28 gestational weeks. The relation between these variables was investigated by evaluating the patients only once. RESULTS: In our study, the mean placental thickness was 31.7 (SD±8.01) mm. The umbilical artery Doppler parameters did not correlate with the placental thickness. The uterine artery Doppler systolic/ diastolic velocity, Pulsatility index and Resistance index values positively correlated with the placental thickness. However, these correlations were not statistically significant. CONCLUSIONS: Although there was no relationship between the placental thickness and obstetric Doppler parameters in this study, we suggest that they are likely important factors and their significance should be evaluated in future studies.
dc.identifier.citationAydın, E. ve Bulut, A. N. (2020). Evaluation of the relationship between placental thickness and obstetric doppler parameters during the second trimester. GORM:Gynecology Obstetrics & Reproductive Medicine, 26(1), 17-20. https://doi.org/10.21613/GORM.2019.1016
dc.identifier.doi10.21613/GORM.2019.1016
dc.identifier.endpage20
dc.identifier.issn1300-4751
dc.identifier.issn2602-4918
dc.identifier.issue1
dc.identifier.startpage17
dc.identifier.urihttps://doi.org/10.21613/GORM.2019.1016
dc.identifier.urihttps://hdl.handle.net/20.500.12511/6745
dc.identifier.volume26
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.relation.ispartofGORM:Gynecology Obstetrics & Reproductive Medicineen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectObstetric
dc.subjectPlacenta
dc.subjectThickness
dc.subjectUltrasonography
dc.titleEvaluation of the relationship between placental thickness and obstetric doppler parameters during the second trimester
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Aydin-Emine-2020.pdf
Boyut:
107.11 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: