Sık kullanılan iki hidrofobik sferik göz içi lensin katarakt cerrahisi sonrası oluşan yüksek sıralı aberasyonlar açısından karşılaştırılması

dc.authorid0000-0002-0972-3833
dc.authorid0000-0002-2563-2149
dc.contributor.authorKaya, Faruk
dc.contributor.authorKoçak, İbrahim
dc.contributor.authorAydın, Ali
dc.contributor.authorBaybora, Hakan
dc.contributor.authorEliaçık, Mustafa
dc.date.accessioned08.07.201910:49:13
dc.date.accessioned2019-07-08T20:18:50Z
dc.date.available08.07.201910:49:13
dc.date.available2019-07-08T20:18:50Z
dc.date.issued2016
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalı
dc.description.abstractAmaç: Ülkemizde sık kullanılan iki hidrofobik sferik lensi, katarakt cerrahisi sonrası oluşan yüksek sıralı aberasyonlar açısından karşılaştırmak. Gereç ve Yöntem: Prospektif ve randomize çalışmamıza, fakoemülsifikasyonla katarakt ameliyatı olup göz içine hidrofobik akrilik lens implantasyonu gerçekleştirilen 38 hastanın 48 gözü dahil edildi. Göz içine farklı hidrofobik sferik lens konan (Focus force F260, Zaraccom veya Acrysof SA 60, Alcon) gözlerden iki grup oluşturuldu. Cerrahi sonrası 90. günde VisxWavescan (Abbott, USA) cihazıyla skotopik şartlarda aberasyonlar ölçüldü ve iki grup arasında anlamlı fark olup olmadığı değerlendirildi. Bulgular: Zaraccom lensi implante edilen grupta cerrahi sonrası değerlendirilen aberasyonlarda toplam RMS (root mean square) değeri 3.18±2.48, yüksek sıralı RMS değeri 0.17±0.19, coma 0.04±0.06, sferik aberasyon -0.004±0.07, trefoil 0.08±0.09 iken; Acrysof lensi implante edilen grupta cerrahi sonrası toplam RMS değeri 1.44±1.40, yüksek sıralı RMS değeri 0.24±0.1, coma 0.13±0.08, sferik aberasyon 0.05±0.06, trefoil 0.14±0.08 olarak bulundu. İki grup karşılaştırıldığında (p=0.05) istatistiksel olarak anlamlı aberasyon farkı bulunmadı (p>0.05). Sonuç: Katarakt cerrahisi sonrası değerlendirilen aberasyonlarda (toplam RMS, yüksek sıralı RMS, sferik aberasyon, coma, trefoil) iki lens arasında istatistiksel anlamlı fark bulunmamıştır.
dc.description.abstractPurpose: To compare two hydrophobic spherical acrylic lenses in terms of their effects on higher order aberrations. Materials and Methods: In this prospective and randomized study 48 eyes of 38 patients who underwent cataract surgery with phacoemulsification and hydrophobic acrylic IOL implantation were included. Two hydrophobic spherical IOL groups were made up. In group 1, Focus force F260, Zaraccom (Anadolu Tıp Teknolojileri, Sivas, Turkey) lenses were implanted in 24 eyes. In group 2, Acrysof SA 60 (Alcon Lab. Inc.,FtWorth, Tex, USA) were used in 24 eyes. Aberrometry was performed on postoperative 90 thday and two groups were compared for higher order aberrations. Results: Postoperative total RMS value was 3.18±2.48 for Zaraccom group. The other values were 0.17±0.19 for higher order RMS, 0.04±0.06 for coma, -0.004±0.07 for spherical aberration, and 0,08±0,09 for trefoil. The results for Acrysof SA 60 group were 1.44±1.40; 0.24±0.1; 0.13±0.08; 0.05±0.06; 0.14±0.08 for total RMS value, higher order RMS value, coma, spherical aberration and trefoil respectively. Conclusion: There was not statistically significant difference between two groups for all aberrometry parameters (p>0.05).
dc.identifier.citationKaya, F., Koçak, İ., Aydın, A., Baybora, H. ve Eliaçık, M. (2016). Sık kullanılan iki hidrofobik sferik göz içi lensin katarakt cerrahisi sonrası oluşan yüksek sıralı aberasyonlar açısından karşılaştırılması. Glokom Katarakt, 11(1), 19-22.
dc.identifier.endpage22
dc.identifier.issn1305-9173
dc.identifier.issue1
dc.identifier.startpage19
dc.identifier.urihttps://hdl.handle.net/20.500.12511/502
dc.identifier.volume11
dc.indekslendigikaynakTR-Dizin
dc.language.isotr
dc.relation.ispartofGlokom Katarakten_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectHidrofobik Sferik
dc.subjectKatarakt Cerrahisi
dc.subjectComparison of Higher
dc.subjectOrder Aberrations in Eyes
dc.subjectCommonly Used Hydrophobic Spherical
dc.subjectGöz İçi Lens
dc.titleSık kullanılan iki hidrofobik sferik göz içi lensin katarakt cerrahisi sonrası oluşan yüksek sıralı aberasyonlar açısından karşılaştırılması
dc.title.alternativeComparison of higher order aberrations in eyes in which two commonly used hydrophobic spherical intraocular lenses are implanted
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
Eliacik-Mustafa-2015.pdf
Boyut:
238.69 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text