Evaluation of corneal thickness with spectral-domain optical coherence tomography following keraring implantation for keratoconus: Five year follow-up

dc.authorid0000-0002-2563-2149
dc.contributor.authorEliaçık, Mustafa
dc.contributor.authorKırgız, Ahmet
dc.contributor.authorAygün, Beril
dc.date.accessioned2020-11-16T06:00:47Z
dc.date.available2020-11-16T06:00:47Z
dc.date.issued2020
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalı
dc.description.abstractTo evaluate the change in the position of intrastromal corneal ring segments (ICRS) implanted in keratoconus patients within five years of implantation. Participants in this study included keratoconus patients who received Keraring 10 ICRS implantation and had a follow-up time of at least 5 years. The distances from apex to anterior corneal surface (AA), from outer basal corner to posterior corneal surface (BP), and from inner basal corner to posterior corneal surface (CP) were measured at every postoperative visit (6 months, 1 year, 3 years, and 5 years) and compared to each other. Thirty eyes of 22 patients were included. The CP showed a statistically significant decrease at all 15 time points (p < .001); however, no statistically significant difference was found at 5 years regarding AA or BP (p > .05 for all). Triangular ICRS implanted in keratoconus patients remained stable for five years without any complications, which is an extremely important aspect of ICRS surgery. The only difference was a slight posterior movement of the inner basal corner, although without anterior chamber perforation.
dc.identifier.citationEliaçık, M., Kırgız, A. ve Aygün, B. (2020). Evaluation of corneal thickness with spectral-domain optical coherence tomography following keraring implantation for keratoconus: Five year follow-up. Current Eye Research, 45(11), 1359-1363. https://dx.doi.org/10.1080/02713683.2020.1749667
dc.identifier.doi10.1080/02713683.2020.1749667
dc.identifier.endpage1363
dc.identifier.issn0271-3683
dc.identifier.issn1460-2202
dc.identifier.issue11
dc.identifier.scopusqualityQ2
dc.identifier.startpage1359
dc.identifier.urihttps://dx.doi.org/10.1080/02713683.2020.1749667
dc.identifier.urihttps://hdl.handle.net/20.500.12511/6029
dc.identifier.volume45
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherTaylor and Francis Ltd.
dc.relation.ispartofCurrent Eye Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectKeratoconus
dc.subjectKeraring Implantation
dc.subjectCorneal Thickness
dc.subjectCoherence Tomography
dc.titleEvaluation of corneal thickness with spectral-domain optical coherence tomography following keraring implantation for keratoconus: Five year follow-up
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Eliacik, Mustafa-2020.pdf
Boyut:
670.6 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: