Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period

dc.authorid0000-0001-8833-5259
dc.contributor.authorSayın Özel, Gülsüm
dc.contributor.authorİnan, Özgür
dc.contributor.authorSeçilmiş Acar, Aslı
dc.contributor.authorAlnıaçık İyidoğan, Gamze
dc.contributor.authorDolanmaz, Doğan
dc.contributor.authorYıldırım, Gülsün
dc.date.accessioned2022-03-17T07:36:06Z
dc.date.available2022-03-17T07:36:06Z
dc.date.issued2021
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı
dc.description.abstractBackground. The surface properties of implants are effective factors for increasing the osseointegration and activity of osteoprogenitor cells. This study compared the stability of dental implants with sandblasted and acid-etched (SLA) and modified surfaces (SLActive) using the resonance frequency analysis (RFA). Methods. In a split-mouth design, 50 dental implants with either SLA surface properties (n = 25) or modified (SLActive) surface properties (n = 25) were placed in the mandibles of 12 patients with a bilateral posterior edentulous area. Implant stability was measured using RFA (Osstell) at implant placement time and every week for 1, 2, and 3 months before the conventional loading time. Results. One week following the implantation, implant stability increased from 70 to 77.67 for SLA and from 71.67 to 79 for SLActive (P [removed] 0.05). Conclusions. For both implant surfaces, increased stability was observed over time, with no significant differences between the groups.
dc.identifier.citationSayın Özel, G., İnan, Ö., Seçilmiş Acar, A., Alnıaçık İyidoğan, G., Dolanmaz, D. ve Yıldırım, G. (2021). Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period. Journal of Dental Research, Dental Clinics, Dental Prospects, 15(4), 226-231. https://doi.org/10.34172/joddd.2021.037
dc.identifier.doi10.34172/joddd.2021.037
dc.identifier.endpage231
dc.identifier.issn2008-210X
dc.identifier.issn2008-2118
dc.identifier.issue4
dc.identifier.pmid35070174
dc.identifier.scopus2-s2.0-85125638571
dc.identifier.scopusqualityQ4
dc.identifier.startpage226
dc.identifier.urihttps://doi.org/10.34172/joddd.2021.037
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9134
dc.identifier.volume15
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorSayın Özel, Gülsüm
dc.language.isoen
dc.publisherTabriz University of Medical Sciences
dc.relation.ispartofJournal of Dental Research, Dental Clinics, Dental Prospectsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsAttribution 4.0 International*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectBone-Implant Interface
dc.subjectDental Implants
dc.subjectOsseointegration
dc.subjectResonance Frequency Analysis
dc.subjectSLA
dc.subjectSLActive
dc.titleStability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Sayın Özel-Gülsüm-2021.pdf
Boyut:
338.46 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: