Effect of different intraoral scanners on the accuracy of bite registration in edentulous maxillary and mandibular arches

dc.authorid0000-0002-0308-9579
dc.contributor.authorRutk?nas, Vygandas
dc.contributor.authorJegelevi?ius, Darius
dc.contributor.authorGedrimien?, Agn?
dc.contributor.authorAuškalnis, Liudas
dc.contributor.authorEyüboğlu, Tan Fırat
dc.contributor.authorÖzcan, Mutlu
dc.contributor.authorHusain, Nadin Al-Haj
dc.contributor.authorAkulauskas, Mykolas
dc.contributor.authorPletkus, Justinas
dc.date.accessioned2024-06-04T05:18:12Z
dc.date.available2024-06-04T05:18:12Z
dc.date.issued2024
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalı
dc.description.abstractObjectives: The objective of this study was to use in vitro models to examine the bite registration accuracy of four different intraoral scanners (IOS) for edentulous maxillary and mandibular arches. The objective was to assess the trueness and precision of the IOS and determine if there were significant differences between them. Methods: An Asiga Max UV 3D printer was used to print maxillary and mandibular edentulous models based on the shape of Frasaco models (artificial dental arch models). Four dental implants were placed symmetrically in both models using Straumann BLT RC implants. Digital impressions were taken with Primescan, Trios 3, Trios 4, and Medit i500 intraoral scanners (n = 10 for each IOS). Digital bite registrations were made, and scanning data was exported in STL format. The accuracy of the interarch distance (the distance between the metrological spheres attached to the mandibular and maxillary models) was estimated for each IOS. Results: The results showed significant differences in trueness and precision between different IOS (p <.05), except Medit i500 and Trios 3 (p >.05). Primescan provided the most accurate results, followed by Medit i500, Trios 3, and Trios 4, respectively. Conclusions: within the limitations of this study, the IOS type affects the accuracy of interocclusal bite registration in in vitro design. Only Primescan achieved clinically acceptable accuracy for the interocclusal recording of edentulous arches. Clinical Relevance: The comparison of the accuracy of bite registration between different intraoral scanners will help increase the efficiency of the clinical application of digitalized interarch registration.
dc.description.sponsorshipLithuanian Business Support Agency.en_US
dc.identifier.citationRutk?nas, V., Jegelevi?ius, D., Gedrimien?, A., Auškalnis, L., Eyüboğlu, T. F., Özcan, M. ... Pletkus, J. (2024). Effect of different intraoral scanners on the accuracy of bite registration in edentulous maxillary and mandibular arches. Journal of Dentistry, 146. http://dx.doi.org/10.1016/j.jdent.2024.105050
dc.identifier.doi10.1016/j.jdent.2024.105050
dc.identifier.issn0300-5712
dc.identifier.pmid38735468
dc.identifier.scopus2-s2.0-85194190052
dc.identifier.scopusqualityQ1
dc.identifier.urihttp://dx.doi.org/10.1016/j.jdent.2024.105050
dc.identifier.urihttps://hdl.handle.net/20.500.12511/12556
dc.identifier.volume146
dc.identifier.wos001250349900001en_US
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorEyüboğlu, Tan Fırat
dc.language.isoen
dc.relation.ecinfo:eu-repo/grantAgreement/MTTP/SK/J05-LVPA-K-01-0055
dc.relation.ispartofJournal of Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAccuracy
dc.subjectDigital Bite Registration
dc.subjectEdentulous
dc.subjectIntraoral Scanner
dc.subjectPrecision
dc.subjectProsthodontics
dc.subjectTrueness
dc.titleEffect of different intraoral scanners on the accuracy of bite registration in edentulous maxillary and mandibular arches
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Eyüboğlu-Tan Fırat-2024.pdf
Boyut:
3.05 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: