Evaluation of heat transfer to the implant-bone interface during removal of metal copings cemented onto titanium abutments

dc.authorid0000-0003-3347-1151
dc.contributor.authorÇakan, Umut
dc.contributor.authorÇakan, Murat
dc.contributor.authorDelilbaşı, Çağrı
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:56:50Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:56:50Z
dc.date.issued2016
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
dc.descriptionWOS: 000376213500018
dc.descriptionPubMed ID: 27148993
dc.description.abstractPurpose: The aim of this investigation was to measure the temperature increase due to heat transferred to the implant-bone interface when the abutment screw channel is accessed or a metal-ceramic crown is sectioned buccally with diamond or tungsten carbide bur using an air rotor, with or without irrigation. Materials and Methods: Cobalt-chromium copings were cemented onto straight titanium abutments. The temperature changes during removal of the copings were recorded over a period of 1 minute. Results: The sectioning of coping with diamond bur and without water irrigation generated the highest temperature change at the cervical part of the implant. Conclusion: Both crown removal methods resulted in an increase in temperature at the implant-bone interface. However, this temperature change did not exceed 47 degrees C, the potentially damaging threshold for bone reported in the literature.
dc.identifier.citationÇakan, U., Çakan, M. ve Delilbaşı, Ç. (2016). Evaluation of heat transfer to the implant-bone interface during removal of metal copings cemented onto titanium abutments. International Journal Of Prosthodontics, 29(3), 290-292. https://dx.doi.org/10.11607/ijp.4561
dc.identifier.doi10.11607/ijp.4561
dc.identifier.endpage292
dc.identifier.issn0893-2174
dc.identifier.issn1942-4426
dc.identifier.issue3
dc.identifier.scopusqualityQ1
dc.identifier.startpage290
dc.identifier.urihttps://dx.doi.org/10.11607/ijp.4561
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2829
dc.identifier.volume29
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal Of Prosthodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEvaluation of Heat
dc.subjectImplant-Bone
dc.subjectRemoval of Metal Copings
dc.subjectCemented Onto Titanium Abutments
dc.titleEvaluation of heat transfer to the implant-bone interface during removal of metal copings cemented onto titanium abutments
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Cakan-Umut 2016.pdf
Boyut:
121.06 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text