Reliable listen-before-talk mechanism for medical implant communication systems

dc.authorid0000-0001-9474-7372
dc.contributor.authorKulaç, Selman
dc.contributor.authorArslan, Hüseyin
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:37:59Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:37:59Z
dc.date.issued2016
dc.departmentİstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik ve Elektronik Mühendisliği Bölümü
dc.description.abstractHealth care applications of wireless communication have been finding places dramatically. One of these applications is communication of implantable medical devices (IMD)s. It is expected that the number of IMDs will increase greatly in the near future. As a result, significant congestion will be experienced in medical implant communication service (MICS) band, leading to interference problems. In this study, we propose reliable listen-before-talk (LBT) mechanism at low signal-to-noise ratios (SNR)s for medical implant communication systems in order to mitigate the interference effects. In our method, we have just brought out power difference between mean peak and mean lowest power spectral values and it provides reliable and simple monitoring of MICS channels' occupation fastly. Our proposed method has superior performance when threshold power level is considered according to the federal communication commission (FCC) Part 95 regulatory standard.
dc.identifier.citationKulaç, S. ve Arslan, H. (2016). Reliable listen-before-talk mechanism for medical implant communication systems. 18th IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) içinde (636-639. ss.). Munich: Germany, September 14-17, 2016. https://dx.doi.org/10.1109/HealthCom.2016.7749531
dc.identifier.doi10.1109/HealthCom.2016.7749531
dc.identifier.endpage636
dc.identifier.isbn9781509033706
dc.identifier.scopusqualityN/A
dc.identifier.startpage639
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1513
dc.identifier.urihttps://dx.doi.org/10.1109/HealthCom.2016.7749531
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.ispartof18th IEEE International Conference on e-Health Networking, Applications and Services (Healthcom)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectAdaptive Frequency Agility
dc.subjectIMD Programmer
dc.subjectListen Before Talk
dc.subjectMetAids Band
dc.subjectMICS Band
dc.subjectWireless IMD Communications
dc.titleReliable listen-before-talk mechanism for medical implant communication systems
dc.typeConference Object

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
Arslan, H..pdf
Boyut:
431.05 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text