Evaluation of the effect of anodization-colored titanium abutments and zirconia substructure thickness on zirconia substructure color: An in vitro study

dc.contributor.authorBaş, B. B.
dc.contributor.authorÇakan, Umut
dc.date.accessioned2023-01-09T12:06:41Z
dc.date.available2023-01-09T12:06:41Z
dc.date.issued2022
dc.departmentİstanbul Medipol Üniversitesi, Sağlık Bilimleri Enstitüsü, Protetik Diş Tedavisi Ana Bilim Dalı
dc.description.abstractBackground and Aim: The aim of this study is to evaluate the effect of anodized titanium abutments and zirconia substructure thickness on the color of zirconia substructure. Materials and Methods: In this study, an electrochemical anodization setup was prepared for titanium coloring. Commercial titanium, anodization-colored yellow and pink titanium, and zirconia were used as different abutment specimens. Thirty zirconia discs in 0.7, 0.9, and 1.1 mm thickness were prepared from zirconia blocks as zirconia substructure specimens (n = 10). Zirconia substructure specimens of different thicknesses were placed on abutment specimens of different colors and L?, a?, b? values were measured with a spectrophotometer device. Color difference (?E) was calculated according to the CIELab formula by comparing the L?, a?, and b? values obtained on the zirconia abutment with the L?, a?, and b? values obtained on the other abutments. Statistical analyzes were performed with two-way analysis of variance and Tukey Honestly Significant Difference (HSD)test (p < 0.05). Results: The increase in the thickness of the substructure resulted in a statistically significant difference on ?E, L?, a?, and b? values (p < 0.001). The effect of abutment color had no significant effect on ?E values. The highest ?E value was 18.10 at zirconia substructure with 0.7 mm thickness when paired with pink-anodized titanium abutment specimens. Conclusion: The thickness of zirconia substructure and the color of titanium abutments affect zirconia substructure color.
dc.identifier.citationBaş, B. B. ve Çakan, U. (2022). Evaluation of the effect of anodization-colored titanium abutments and zirconia substructure thickness on zirconia substructure color: An in vitro study. Nigerian Journal of Clinical Practice, 25(12), 2024-2029. https://dx.doi.org/10.4103/njcp.njcp_484_22
dc.identifier.doi10.4103/njcp.njcp_484_22
dc.identifier.endpage2029
dc.identifier.issn1119-3077
dc.identifier.issue12
dc.identifier.pmid36537461
dc.identifier.scopus2-s2.0-85144249087
dc.identifier.scopusqualityQ3
dc.identifier.startpage2024
dc.identifier.urihttps://dx.doi.org/10.4103/njcp.njcp_484_22
dc.identifier.urihttps://hdl.handle.net/20.500.12511/10269
dc.identifier.volume25
dc.identifier.wos000904875900013en_US
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorBaş, B. B.
dc.language.isoen
dc.publisherWolters Kluwer Medknow Publications
dc.relation.ispartofNigerian Journal of Clinical Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAbutment
dc.subjectAnodized Titanium
dc.subjectColor Change
dc.subjectSpectrophotometry
dc.subjectZirconia
dc.titleEvaluation of the effect of anodization-colored titanium abutments and zirconia substructure thickness on zirconia substructure color: An in vitro study
dc.typeArticle

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: