Bond strength of resin composite to light activated bleached enamel

dc.contributor.authorYavuz, Tevfik
dc.contributor.authorÖzyılmaz, Özgün Yusuf
dc.contributor.authorÖztürk, Atiye Nilgun
dc.contributor.authorAykent, Filiz
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T20:02:05Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T20:02:05Z
dc.date.issued2016
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı
dc.descriptionWOS: 000391532500014
dc.descriptionPubMed ID: 27811449
dc.description.abstractObjectives: This study evaluated the microtensile bond strength (mu TBS) of a resin composite bonded to bleached enamel as a function of bleaching conditions. Materials and Methods: The whiteness hydrogen peroxide (HP) bleaching agent containing 35% HP was applied to the central incisors' facial enamel surface and irradiated as follows: No treatment (G1; control); no light (G2); light-emitting diode, the 40s (G3); diode laser, the 20s (G4); and neodymium: yttrium aluminum garnet laser, 20s (G5). A Variolink II resin composite structure was then built up incrementally on the surface. The teeth were sectioned into three 1.2 mm x 1.2 mm wide "I"-shaped sections. The specimens were then subjected to microtensile testing at a crosshead speed of 1 mm/min. Data were analyzed using one-way ANOVA (alpha = 0.05) followed by the Tukey Honestly Significant Difference post-hoc test. The fractured surfaces were observed with a stereomicroscope at x 100 magnification. Results: One-way ANOVA revealed no statistical differences among the groups (P > 0.05). No differences appeared between the groups bonded 14 days after bleaching (P > 0.05). Mean mu TBS values (MPa) were as follows: 22.05 +/- 5.01 (G1); 19.6 +/- 5.6 (G2); 19.3 +/- 5.4 (G3); 20.08 +/- 2.08 (G4); and 18.1 +/- 4.8 (G5). Many adhesive failures occurred at the bleached and irradiated enamel surfaces. Conclusion: The various irradiation treatments following the application of the whiteness HP bleaching agent to enamel did not significantly reduce the mu TBS within a 14-day period.
dc.identifier.citationYavuz, T., Özyılmaz, Ö. Y., Öztürk, A. N. ve Aykent, F. (2016). Bond strength of resin composite to light activated bleached enamel. Nigerian Journal of Clinical Practice, 19(6), 766-771. https://dx.doi.org/10.4103/1119-3077.178909
dc.identifier.doi10.4103/1119-3077.178909
dc.identifier.endpage771
dc.identifier.issn1119-3077
dc.identifier.issue6
dc.identifier.scopusqualityQ3
dc.identifier.startpage766
dc.identifier.urihttps://dx.doi.org/10.4103/1119-3077.178909
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3543
dc.identifier.volume19
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWolters Kluwer Medknow Publications
dc.relation.ispartofNigerian Journal of Clinical Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 Unported*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/*
dc.subjectBleaching Agents
dc.subjectLasers
dc.subjectLasers Neodymium: Yttrium Aluminum Garnet
dc.subjectResin Bonding
dc.subjectTooth Bleaching
dc.titleBond strength of resin composite to light activated bleached enamel
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Yavuz, Tevfik.pdf
Boyut:
1.12 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text