The influence of blood and/or hemostatic agent contamination on Micro-TBS to dentin

dc.authorid0000-0003-3460-4382
dc.authorid0000-0002-8310-2410
dc.contributor.authorKaraman, Emel
dc.contributor.authorTuncer, Duygu
dc.contributor.authorToz, Tuğba
dc.contributor.authorKuşdemir, Mahmut
dc.contributor.authorGenç, Gencay
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:57:15Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:57:15Z
dc.date.issued2015
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
dc.descriptionWOS: 000353474900001
dc.description.abstractAim: The purpose of this study was to evaluate the effects of blood contamination and hemostatic agent Ankaferd Blood Stopper (ABS: Ankaferd Drug Inc, Istanbul, Turkey) on the microtensile bond strength of a self-etching adhesive. Material and methods: Flat dentin surfaces were created from 40-M teeth and randomly divided to four groups according to contamination and adhesive procedure. The specimens of Group 1 are contaminated with blood; ABS was applied to the specimens of Group 2 after blood contamination and applied to the specimens of Group 3 without blood contamination. Group 4 is control group and self-etching adhesive was applied to all specimens. Teeth were restored with a nanohybrid composite. The specimens were sectioned to the beams and microtensile testing was carried out and the data were statistically analyzed with analysis of variance test. Tukey's honestly significant difference post hoc test was also performed for multiple comparisons to compare subgroups. Results: Group 4 had the highest strength value, followed by Group 3, while Group 1, which contacts only with blood, had the lowest strength value. Conclusion: ABS has a negative effect on the bond strength of one-step self-etching adhesive system.
dc.identifier.citationKaraman, E., Tuncer, D., Toz, T., Kuşdemir, M. ve Genç, G. (2015). The influence of blood and/or hemostatic agent contamination on Micro-TBS to dentin. Journal of Adhesion Science and Technology, 29(13), 1295-1300. https://dx.doi.org/10.1080/01694243.2015.1025465.
dc.identifier.doi10.1080/01694243.2015.1025465
dc.identifier.endpage1300
dc.identifier.issn0169-4243
dc.identifier.issn1568-5616
dc.identifier.issue13
dc.identifier.scopusqualityQ2
dc.identifier.startpage1295
dc.identifier.urihttps://dx.doi.org/10.1080/01694243.2015.1025465
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2936
dc.identifier.volume29
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTaylor & Francis
dc.relation.ispartofJournal of Adhesion Science and Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHemostatic Agent Contamination
dc.subjectBlood Contamination
dc.subjectMicro-TBS
dc.titleThe influence of blood and/or hemostatic agent contamination on Micro-TBS to dentin
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
kuşdemir, mahmut-2015.pdf
Boyut:
141.4 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text