Cryoablation of septal accessory pathways in children: Midterm results

dc.contributor.authorKaradeniz, Cem
dc.contributor.authorAkdeniz, Celal
dc.contributor.authorTuran, Özlem
dc.contributor.authorTuzcu, Volkan
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T20:02:20Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T20:02:20Z
dc.date.issued2014
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
dc.descriptionWOS: 000342833000003
dc.descriptionPubMed ID: 25039285
dc.description.abstractBackground: Radiofrequency (RF) catheter ablation in the septal arrhythmia substrates has an increased risk of irreversible atrioventricular block. Despite its safety profile, several studies reported a lower acute success rate and a higher recurrence rate with cryoablation of septal accessory pathways (APs) when compared to RF ablation. The aim of this study was to assess the efficacy and safety of cryoablation of right septal APs using an electroanatomical mapping system guidance. Methods and Results: A total of 43 consecutive patients (13.2 +/- 5.5 years) underwent cryoablation for right septal APs. The EnSite system (St. Jude Medical, St. Paul, MN, USA) was used in all procedures. No fluoroscopy was used in 90% of patients (39/43). The mean fluoroscopy time in the remaining four patients was 3.7 +/- 0.7 minutes. An electrophysiology catheter with 2-mm distal spacing was used to determine the precise AP location. The majority of the patients (20/43) had anteroseptal, and remaining of the patients had posteroseptal (15/43) and midseptal (8/43) APs. A 6-mm-tip catheter was used in 33 patients and 8-mm-tip catheter was used in nine patients (both catheters were used in one patient). The mean procedure duration and number of complete cryoablation lesions were 181.5 +/- 60.6 minutes and 6.1 +/- 3.1 minutes, respectively. Acute success was achieved in 40 of 43 patients (93%). No complications were noted. During a mean follow-up of 8.8 +/- 4.8 months, five patients (12.5%) experienced recurrence. Conclusions: Our data suggest that cryoablation of septal APs can be performed safely with comparable efficacy to the reported RF ablation results using a limited fluoroscopy approach.
dc.identifier.citationKaradeniz, C., Akdeniz, C., Turan, Ö. ve Tuzcu, V. (2014). Cryoablation of septal accessory pathways in children: Midterm results. Pacing and Clinical Electrophysiology, 37(9), 1095-1099. https://dx.doi.org/10.1111/pace.12442
dc.identifier.doi10.1111/pace.12442
dc.identifier.endpage1099
dc.identifier.issn0147-8389
dc.identifier.issn1540-8159
dc.identifier.issue9
dc.identifier.scopusqualityQ2
dc.identifier.startpage1095
dc.identifier.urihttps://dx.doi.org/10.1111/pace.12442
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3619
dc.identifier.volume37
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWiley-Blackwell
dc.relation.ispartofPacing and Clinical Electrophysiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectArrhythmia
dc.subjectAtrioventricular Block
dc.subjectCryoablation
dc.subjectRadiofrequency Ablation
dc.subjectRecurrence
dc.titleCryoablation of septal accessory pathways in children: Midterm results
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
Karadeniz, Cem-2014.pdf
Boyut:
83.67 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text