Effect of glide path creating on cyclic fatigue resistance of reciproc and reciproc blue nickel-titanium files: A laboratory study

dc.authorid0000-0001-8656-7101
dc.contributor.authorÖzyürek, Taha
dc.contributor.authorUslu, Gülşah
dc.contributor.authorYılmaz, Koray
dc.contributor.authorGündoğar, Mustafa
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:50:33Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:50:33Z
dc.date.issued2018
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalı
dc.descriptionWOS: 000434907000021
dc.descriptionPubMed ID: 29680720
dc.description.abstractIntroduction: The purpose of this article was to compare the cyclic fatigue resistance of Reciproc and Reciproc Blue files (VDW GmbH, Munich, Germany) that were used to prepare root canals of mandibular molar teeth with or without a glide path. Methods: Sixty Reciproc R25 and 60 Reciproc Blue R25 files were used. The Reciproc and Reciproc Blue groups were divided into 3 subgroups (ie, as received condition, used without a glide path, and used with a glide path). All the instruments were rotated in a stainless steel artificial canal with an inner diameter of 1.5 mm, a 60 angle of curvature, and a radius of curvature of 5 mm until fracture occurred. The number of cycle to fracture was calculated, and the length of the fractured segments was measured. The Kruskal-Wallis test was performed to statistically analyze the data using SPSS 21.0 software (IBM Corp, Armonk, NY) at a 5% significance level. Results: The cyclic fatigue resistance of as received condition Reciproc Blue files was found to be higher than as received condition Reciproc files (P <.05). Reciproc Blue files used for root canal preparation showed higher cyclic fatigue resistance than Reciproc files used for root canal preparation (P <.05). There was no statistically significant difference between Reciproc and Reciproc Blue files used with a glide path and without a glide path (P> .05). There was no statistically significant difference in the mean length of the fractured fragments of the instruments (P> .05). Conclusions: Within the limitations of this in vitro study, it was concluded that creating a glide path using ProGlider files had no effect on the cyclic fatigue resistance of RPC and RPC Blue files.
dc.identifier.citationÖzyürek, T., Uslu, G., Yılmaz, K. ve Gündoğar, M. (2018). Effect of glide path creating on cyclic fatigue resistance of reciproc and reciproc blue nickel-titanium files: A laboratory study. Journal of Endodontics, 44(6), 1033-1037. https://dx.doi.org/10.1016/j.joen.2018.03.004
dc.identifier.doi10.1016/j.joen.2018.03.004
dc.identifier.endpage1037
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.issue6
dc.identifier.scopusqualityQ1
dc.identifier.startpage1033
dc.identifier.urihttps://dx.doi.org/10.1016/j.joen.2018.03.004
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2014
dc.identifier.volume44
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Science Inc
dc.relation.ispartofJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectCyclic Fatigue
dc.subjectGlide Path
dc.subjectNickel Titanium
dc.subjectReciproc
dc.subjectReciproc Blue
dc.titleEffect of glide path creating on cyclic fatigue resistance of reciproc and reciproc blue nickel-titanium files: A laboratory study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
Gündoğar, M..pdf
Boyut:
804.84 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text