Are perioperative near-infrared spectroscopy values correlated with clinical and biochemical parameters in cyanotic and acyanotic infants following corrective cardiac surgery?

dc.authorid0000-0001-8532-4917
dc.authorid0000-0002-0799-4875
dc.authorid0000-0003-4856-0974
dc.contributor.authorErsoy, Cihangir
dc.contributor.authorÖzyüksel, Arda
dc.contributor.authorBozkaya Alkan, Tijen
dc.contributor.authorKaraaslan, Pelin
dc.contributor.authorÖrmeci, Tuğrul
dc.contributor.authorÜndar, Akif
dc.contributor.authorAkçevin, Atıf
dc.contributor.authorTürkoğlu, Halil
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T20:02:30Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T20:02:30Z
dc.date.issued2016
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Kalp ve Damar Cerrahisi Ana Bilim Dalı
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalı
dc.descriptionWOS: 000371172200007
dc.descriptionPubMed ID: 26034194
dc.description.abstractBackground: Near-infrared spectroscopy (NIRS) is a useful non-invasive tool for monitoring infants undergoing cardiac surgery. In this study, we aimed to determine the NIRS values in cyanotic and acyanotic patients who underwent corrective cardiac surgery for congenital heart diseases. Methods: Thirty consecutive infants who were operated on with the diagnosis of ventricular septal defect (n=15) and tetralogy of Fallot (n=15) were evaluated retrospectively. A definitive repair of the underlying cardiac pathology was achieved in all cases. A total of six measurements of cerebral and renal NIRS were performed at different stages of the perioperative period. The laboratory data, mean urine output and serum lactate levels were evaluated along with NIRS values in each group. Results: The NIRS values differ in both groups, even after the corrective surgical procedure is performed. The recovery of renal NIRS values is delayed in the cyanotic patients. Conclusion: Even though definitive surgical repair is performed in cyanotic infants, recovery of the renal vasculature may be delayed by up to two days, which is suggestive of a vulnerable period for renal dysfunction.
dc.identifier.citationErsoy, C., Özyüksel, A., Bozkaya Alkan, T., Karaaslan, P., Örmeci, T., Ündar, A. ... Türkoğlu, H. (2016). Are perioperative near-infrared spectroscopy values correlated with clinical and biochemical parameters in cyanotic and acyanotic infants following corrective cardiac surgery? Perfusion-Uk, 31(2), 125-130. https://dx.doi.org/10.1177/0267659115588632
dc.identifier.doi10.1177/0267659115588632
dc.identifier.endpage130
dc.identifier.issn0267-6591
dc.identifier.issn1477-111X
dc.identifier.issue2
dc.identifier.scopusqualityQ1
dc.identifier.startpage125
dc.identifier.urihttps://dx.doi.org/10.1177/0267659115588632
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3662
dc.identifier.volume31
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSage Publications Ltd
dc.relation.ispartofPerfusion-Uken_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectNear-Infrared Spectroscopy
dc.subjectTetralogy of Fallot
dc.subjectVentricular Septal Defect
dc.subjectPediatric Cardiac Surgery
dc.subjectRenal Circulation
dc.titleAre perioperative near-infrared spectroscopy values correlated with clinical and biochemical parameters in cyanotic and acyanotic infants following corrective cardiac surgery?
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Ersoy-Cihangir 2016.pdf
Boyut:
778.38 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text