dc.description.abstractThis study aims to determine the effectiveness of a retrofitting technique based on the seismic performance analysis results comparison between two inactive multi-storey reinforced concrete (RC) buildings for a long period. Their seismic performance is determined according to the latest Turkish Building Earthquake Code (TBEC-2018) recommendations. The main difference between the examined buildings is the reinforcement (retrofit) technique applied to one of them with additional new shear walls. The whole process was demonstrated with a code-based approach, and the results were compared after the performance evaluation. The structural system geometry, member dimensions and plan layout of the buildings are checked with the original design projects by making on-site measurements. The material properties of the buildings are determined by field studies and laboratory studies. Buildings are modelled with finite element software, and numerical simulations are performed to determine the seismic performance levels according to existing code. As a result of the analysis, the effectiveness of the retrofit approach was examined by comparing the structural behaviour and seismic performance levels of both buildings. The results showed the importance of some parameters that should be taken into account in the retrofitting process with the addition of new shear walls to RC structures. While the applied retrofit process increased the stiffness of the structure and decreased the displacements, the results indicated a failure with a shear-critical condition.
dc.identifier.citationÇoşgun, T., Sayın, B., Güneş, B. ve Mangır, A. (2022). Retrofitting technique effectiveness and seismic performance of multi-rise RC buildings: A case study. Case Studies in Construction Materials, 16. https://doi.org/10.1016/j.cscm.2022.e00931
dc.identifier.doi10.1016/j.cscm.2022.e00931
dc.identifier.issn2214-5095
dc.identifier.scopus2-s2.0-85124163374
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.cscm.2022.e00931
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9030
dc.identifier.volume16
dc.identifier.wos000788093300005en_US
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorMangır, Atakan
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofCase Studies in Construction Materialsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectField Study
dc.subjectLaboratory Tests
dc.subjectNumerical Analysis
dc.subjectRC Buildings
dc.subjectRetrofitting
dc.subjectSeismic Performance
dc.titleRetrofitting technique effectiveness and seismic performance of multi-rise RC buildings: A case study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Mangir-Atakan-2022.pdf
Boyut:
14.85 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: