Comparison of tricuspid and mitral annular plane systolic excursion in determination of acute blood loss in healthy volunteers

dc.authorid0000-0003-2641-3965
dc.contributor.authorSarıhan, Aydın
dc.contributor.authorGüllüpınar, Birdal
dc.contributor.authorSağlam, Caner
dc.contributor.authorKaragöz, Arif
dc.contributor.authorTandon, Shikha
dc.contributor.authorTurhan, Ajda
dc.contributor.authorKoran, Serhat
dc.contributor.authorÜnlüer, Erden Erol
dc.date.accessioned2024-01-11T09:57:53Z
dc.date.available2024-01-11T09:57:53Z
dc.date.issued2023
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Aile Hekimliği Ana Bilim Dalı
dc.description.abstractUltrasound is used more and more in determining acute blood loss. This study is to compare tricuspid annular plane systolic excursion (TAPSE) and mitral annular plane systolic excursion (MAPSE) measurement to determine volume loss pre and post blood donation in healthy volunteers. The systolic, diastolic and mean arterial blood pressures and pulses of the donors were measured in the standing and supine position by the attending physician, then, inferior vena cava (IVC), TAPSE and MAPSE measurements were made pre and post blood donation. Statistically significant differences were found in systolic blood pressure and pulse rate values that obtained in the standing position, and in the systolic blood pressure, diastolic blood pressure, mean arterial pressure and pulse values that obtained in the supine position (p < 0.05). The difference between IVC expiration (IVCexp) pre and post blood donation was 4.76 +/- 2.94 mm, and the difference in IVC inspiration (IVCins) was 2.73 +/- 2.91 mm. In addition, the MAPSE and TAPSE differences were 2.16 +/- 1.4 mm and 2.98 +/- 2.13 mm, respectively. Statistically significant differences were found between IVCins-exp, TAPSE and MAPSE values. TAPSE and MAPSE can be helpful in the early diagnosis of acute blood loss.
dc.identifier.citationSarıhan, A., Güllüpınar, B., Sağlam, C., Karagöz, A., Tandon, S., Turhan, A. ... Ünlüer, E. E. (2023). Comparison of tricuspid and mitral annular plane systolic excursion in determination of acute blood loss in healthy volunteers. Internal and Emergency Medicine, 18(5), 1543-1550. https://dx.doi.org/10.1007/s11739-023-03246-3
dc.identifier.doi10.1007/s11739-023-03246-3
dc.identifier.endpage1550
dc.identifier.issn1828-0447
dc.identifier.issn1970-9366
dc.identifier.issue5
dc.identifier.pmid36929348
dc.identifier.scopus2-s2.0-85150218344
dc.identifier.scopusqualityQ1
dc.identifier.startpage1543
dc.identifier.urihttps://dx.doi.org/10.1007/s11739-023-03246-3
dc.identifier.urihttps://hdl.handle.net/20.500.12511/12124
dc.identifier.volume18
dc.identifier.wos000952902800004en_US
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorKoran, Serhat
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofInternal and Emergency Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAcute Blood Loss
dc.subjectEarly Diagnosis
dc.subjectMitral Annular Plane Systolic Excursion
dc.subjectTricuspid Annular Plane Systolic Excursion
dc.titleComparison of tricuspid and mitral annular plane systolic excursion in determination of acute blood loss in healthy volunteers
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Koran-Serhat-2023.pdf
Boyut:
1.03 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: