Comparison of photorefraction, autorefractometry and retinoscopy in children

dc.authorid0000-0002-5079-4713
dc.authorid0000-0001-8954-5055
dc.authorid0000-0002-2563-2149
dc.contributor.authorDemirci, Göktuğ
dc.contributor.authorArslan, Banu
dc.contributor.authorÖzsütçü, Mustafa
dc.contributor.authorEliaçık, Mustafa
dc.contributor.authorGülkilik, Gökhan
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:57:00Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:57:00Z
dc.date.issued2014
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalı
dc.descriptionWOS: 000341838400003
dc.descriptionPubMed ID: 24114503
dc.description.abstractPhotorefractive devices have been evaluated for their effectiveness in detecting anisometropia, hyperopia, myopia, and astigmatism. We investigated the reliability of Plusoptix S08, the newest photoscreener, and Topcon autorefractometer by comparing them with cycloplegic retinoscopy. Plusoptix S08, cycloplegic retinoscopy, and cycloplegic autorefractometer measurements for 235 eyes of 118 children (59 female, 59 male) with a mean age of 4.9 +/- 2.6 and median age of 5 years (range 1-12) were conducted. The Plusoptix S08 produced the following mean (+/- SD) results-spherical 0.27 +/- 1.64, cylindrical power -0.81 +/- 0.71, axis 89.73 +/- 61.18, and spherical equivalent -0.05 +/- 1.61. The cycloplegic retinoscopy produced the following mean (+/- SD) results-spherical 0.12 +/- 1.35, cylindrical power -0.89 +/- 0.71, axis 92.18 +/- 68.39, and spherical equivalent -0.15 +/- 1.31. The cycloplegic autorefractometer produced the following mean (+/- SD) results-spherical 0.16 +/- 1.44, cylindrical power -0.88 +/- 0.72, axis 90.86 +/- 68.21, and spherical equivalent -0.12 +/- 1.41. This study has shown that cycloplegic autorefractometer and retinoscopy results are similar and Plusoptix S08 is a very safe, easy-to-use and reliable screening method of refraction, especially for ophthalmologists unskilled in retinoscopy. Plusoptix S08 is a useful tool for estimating refraction in patients for whom conventional autorefraction is not an option.
dc.identifier.citationDemirci, G., Arslan, B., Özsütçü, M., Eliaçık, M. ve Gülkilik, G. (2014). Comparison of photorefraction, autorefractometry and retinoscopy in children. International Ophthalmology, 34(4), 739-746. https://dx.doi.org/10.1007/s10792-013-9864-x
dc.identifier.doi10.1007/s10792-013-9864-x
dc.identifier.endpage746
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.issue4
dc.identifier.scopusqualityQ2
dc.identifier.startpage739
dc.identifier.urihttps://dx.doi.org/10.1007/s10792-013-9864-x
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2875
dc.identifier.volume34
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofInternational Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectRetinoscopy
dc.subjectPhotorefraction
dc.subjectAutorefractometry
dc.titleComparison of photorefraction, autorefractometry and retinoscopy in children
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Demirci, Goktug-2014.pdf
Boyut:
424.88 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text