Effects of storage time and restoration depth on instrumental color adjustment potential of universal resin composites

dc.contributor.authorAkgül, Sinem
dc.contributor.authorGündoğdu, Ceyda
dc.contributor.authorBala, Oya
dc.date.accessioned2022-02-03T06:48:19Z
dc.date.available2022-02-03T06:48:19Z
dc.date.issued2022
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Ana Bilim Dalı
dc.description.abstractPurpose: To determine the instrumental color adjustment potential (CAP-I) of 3 universal composites at 2 time intervals and 2 depths. Methods: Omnichroma, Estelite Sigma Quick, and Filtek Universal Restorative were tested. Two types of specimens were prepared. For dual specimens, Class V restorations were created in anterior denture teeth and restored with resin composites. For single specimens, replications were fabricated with resin composites (n = 10). Unrestored teeth were used for comparison. Color was measured with a spectrophotometer at 24 h and 1 month, and CAP-I was calculated. Data were compared by analysis of variance followed by the Student t-test and paired sample t-test. Results: The CAP-I of tested materials ranged from 0.11 to 0.27 at 24 h and from 0.60 to 0.76 at 1 month. At 24 h, Omnichroma yielded the highest values, followed by Estelite Sigma Quick and Filtek Universal Restorative (P < 0.05). CAP-I was significantly higher at 1 month than at 24 h in all groups. In all groups, restorations with a depth of 3.0 mm yielded better results than restorations with a depth of 2.0 mm (P < 0.05). Conclusion: Storage time and restoration depth were positively associated with CAP-I. Single-shade and multi-shade universal composites are good alternatives for color-matched, esthetically satisfying restorations.
dc.identifier.citationAkgül, S., Gündoğdu, C. ve Bala, O. (2022). Effects of storage time and restoration depth on instrumental color adjustment potential of universal resin composites. Journal of Oral Science, 64(1), 49-52. https://dx.doi.org/10.2334/josnusd.21-0290
dc.identifier.doi10.2334/josnusd.21-0290
dc.identifier.endpage52
dc.identifier.issn1343-4934
dc.identifier.issn1880-4926
dc.identifier.issue1
dc.identifier.pmid34911896
dc.identifier.scopus2-s2.0-85123812721
dc.identifier.scopusqualityQ3
dc.identifier.startpage49
dc.identifier.urihttps://dx.doi.org/10.2334/josnusd.21-0290
dc.identifier.urihttps://hdl.handle.net/20.500.12511/8953
dc.identifier.volume64
dc.identifier.wos000746122400010en_US
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherNihon University
dc.relation.ispartofJournal of Oral Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBlending Effect
dc.subjectColor Adjustment Potential
dc.subjectSpectrophotometer
dc.subjectUniversal Resin Composite
dc.titleEffects of storage time and restoration depth on instrumental color adjustment potential of universal resin composites
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Gündoğdu-Ceyda-2022.pdf
Boyut:
749.57 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: