Cyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne gold, and twisted file adaptive rotary files under different temperatures and ambient conditions

dc.authorid0000-0001-8656-7101
dc.contributor.authorGündoğar, Mustafa
dc.contributor.authorÖzyürek, Taha
dc.contributor.authorYılmaz, Koray
dc.contributor.authorUslu, Gülşah
dc.date.accessioned2020-03-23T07:04:57Z
dc.date.available2020-03-23T07:04:57Z
dc.date.issued2019
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalı
dc.description.abstractBackground. This study examined the effects of changes in temperature and environmental conditions on the cyclic fatigue resistance of Reciproc Blue, HyFlex EDM, WaveOne Gold, and Twisted File Adaptive. Methods. Forty-five Reciproc Blue (25/.08), 45 HyFlex EDM (25/.08), 45 WaveOne Gold (25/.07), and 45 Twisted File Adaptive (25/.08) files were tested for cyclic fatigue at room temperature (20°C) in air and water and at body temperature (35°C) in water. All the instruments were rotated in artificial canals made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius of curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds, using a digital chronometer. Mann-Whitney U test was used for the statistical analysis of data, with SPSS 21.0. Results. Cyclic fatigue resistance was significantly higher in all the groups in water at an ambient temperature of 20°C compared with air and water at temperatures of 20°C and 35°C, respectively (P<0.05). The intragroup analysis revealed that HyFlex EDM had the highest cyclic fatigue resistance, followed by Reciproc Blue, WaveOne Gold, and Twisted File Adaptive in both air and water at 20°C (P<0.05). HyFlex EDM exhibited the highest cyclic fatigue resistance in water at 35°C, whereas there was no significant difference between the other groups (P>0.05). Conclusion. Within the limitations of the present study, an increase in the ambient temperature significantly decreased the cyclic fatigue resistance of the tested NiTi files.
dc.identifier.citationGündoğar, M., Özyürek, M., Yılmaz, K. ve Uslu, G. (2017). Cyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne Gold, and Twisted File Adaptive rotary files under different temperatures and ambient conditions. Journal of Dental Research Dental Clinics Dental Prospects, 13(3), 166-171. http://doi.org/10.15171/joddd.2019.026
dc.identifier.doi10.15171/joddd.2019.026
dc.identifier.endpage171
dc.identifier.issue3
dc.identifier.startpage166
dc.identifier.urihttp://doi.org/10.15171/joddd.2019.026
dc.identifier.urihttps://hdl.handle.net/20.500.12511/5060
dc.identifier.volume13
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.relation.ispartofJournal of Dental Research Dental Clinics Dental Prospectsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCyclic Fatigue
dc.subjectHyFlex EDM
dc.subjectReciproc Blue
dc.subjectStatic Test
dc.subjectWaveOne Gold
dc.titleCyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne gold, and twisted file adaptive rotary files under different temperatures and ambient conditions
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
gundogar(2019).pdf
Boyut:
385.63 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: