Effect of a pedicle screw fixation system on lumbar spinal segments: A finite element study

dc.authorid0000-0003-2601-143X
dc.contributor.authorAkıncı, Saliha Zeyneb
dc.contributor.authorKarabulut, Derya
dc.contributor.authorDoğru, Suzan Cansel
dc.contributor.authorSürmen, Hasan Kemal
dc.contributor.authorYaman, Onur
dc.contributor.authorArslan, Yunus Ziya
dc.date.accessioned2024-06-11T12:48:40Z
dc.date.available2024-06-11T12:48:40Z
dc.date.issued2023
dc.departmentİstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Biyomedikal Mühendisliği Bölümü
dc.description.abstractObjective: Spinal implants have been used to stimulate fusion by surgical adjustment and correct abnormal alignment of the vertebral column. Spinal fusion can cause some spinal disorders and hence describing the changes in biomechanical forces would help to understand these complications. In this study, we used two lumbar mod-els. One of them is used without the fixed pedicle screw system, and the other one was used with that system. Therefore, we aimed to investigate the biomechanical effect of a pedicle screw fixation system on the lumbar functional spinal unit under applied forces. Material and Meth-ods: Computed tomography data of a scoliotic patient was used for the construction of the lumbar models. The second and third vertebrae (L2-L3) of the lumbar spine, two facet joints, an intervertebral disc, and ligaments were constructed. A screw fixation system was employed and Von-Mises stress analysis was carried out for both models. Results: The von Mises stress distribution results showed that the presence of fixed implantation transmitted the compressive forces to the screws and rods in all directions and decreased the stress levels considerably by al-lowing to stabilize the model. The upper side of the L2 vertebra was the most affected region in flexion and lateral bending. However, the pedi-cle region had the maximum affected area under applied loads in ex-tension and axial rotation. Conclusion: It was concluded that a fixed implant system preserves the maintenance of the vertebral column and decreases the stress on the adjacent spinal segments, especially for the intervertebral discs.
dc.identifier.citationAkıncı, S. Z., Karabulut, D., Doğru, S. C., Sürmen, H. K., Yaman, O. ve Arslan, Y. Z. (2023). Effect of a pedicle screw fixation system on lumbar spinal segments: A finite element study. Turkiye Klinikleri Journal of Medical Sciences, 43(4), 372-381. http://dx.doi.org/10.5336/medsci.2023-99005
dc.identifier.doi10.5336/medsci.2023-99005
dc.identifier.endpage381
dc.identifier.issn1300-0292
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85194249534
dc.identifier.scopusqualityQ4
dc.identifier.startpage372
dc.identifier.urihttp://dx.doi.org/10.5336/medsci.2023-99005
dc.identifier.urihttps://hdl.handle.net/20.500.12511/12623
dc.identifier.volume43
dc.indekslendigikaynakScopus
dc.institutionauthorAkıncı, Saliha Zeyneb
dc.language.isoen
dc.relation.ispartofTurkiye Klinikleri Journal of Medical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFinite Element Analysis
dc.subjectLumbar Vertebrae
dc.subjectPedicle Screws
dc.subjectSpine
dc.titleEffect of a pedicle screw fixation system on lumbar spinal segments: A finite element study
dc.title.alternativePedikül vidalı sabitleme sisteminin lomber spinal segmentler üzerindeki etkisi: Sonlu elemanlar çalışması
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Akıncı-Saliha Zeyneb-2023.pdf
Boyut:
3.89 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: