Biomechanical and morphometric properties of the long flexor tendons of the toes: A cadaver study

dc.authorid0000-0003-2537-4976
dc.contributor.authorBeger, Orhan
dc.contributor.authorTumentemur, Gamze
dc.contributor.authorUzun, Coşar
dc.contributor.authorKeskinöz, Elif Nedret
dc.contributor.authorElvan, Özlem
dc.contributor.authorUzmansel, Deniz
dc.contributor.authorKeskinbora, Mert
dc.contributor.authorErdal, Nurten
dc.contributor.authorTaşdelen, Bahar
dc.contributor.authorKurtoğlu, Zeliha
dc.date.accessioned2019-12-23T08:58:54Z
dc.date.available2019-12-23T08:58:54Z
dc.date.issued2019
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalı
dc.description.abstractBACKGROUND: We sought to show the biomechanical and morphometric properties of flexor hallucis longus (FHL) and flexor digitorum longus (FDL) tendon grafts harvested by specific surgical approaches and to assess the contribution of FHL slips to the long flexor tendons of the toes. METHODS: Thirteen fresh-frozen amputated feet (average age, 79 years) were dissected. The connections between the FHL and FDL tendons and the contribution of FHL slips to the long flexor tendons were classified. The biomechanical properties of the tendons and slips were measured using a tensile device. RESULTS: The connections between the FHL and FDL tendons were reviewed in two groups. Group 1 had FHL slips (11 cases) and group 2 had cross-slips (two cases). The FHL slips joined the second and third toe long flexor tendon structures. Tendon length decreased significantly from the second to the fifth toe (P < .001). Apart from the second toe tendon being thicker than that of the fourth toe (P = .02) and Young's modulus being relatively smaller in the third versus the fourth toe tendon (P = .01), biomechanical and morphometric properties of second to fourth tendons were similar. Mechanical properties of those tendons were significantly different from fifth toe tendons and FHL slips. Morphometric and biomechanical properties of FHL slips were similar to those of the fifth toe tendon. CONCLUSIONS: Herein, FHL slips were shown to have biomechanical properties that might contribute to flexor functions of the toes. During the harvesting of tendon grafts from the FHL by minimally invasive incision techniques from the distal plane of the master knot of Henry, cutting slips between FHL and FDL tendons could be considered a cause of postoperative function loss in toes.
dc.identifier.citationBeger, O., Tumentemur, G., Uzun, C., Keskinöz, E. N., Elvan, Ö., Uzmansel, D. ... Kurtoğlu, Z. (2019). Biomechanical and morphometric properties of the long flexor tendons of the toes: A cadaver study. Journal of the American Podiatric Medical Association, 109(4), 182-290. http://doi.org/10.7547/17-063
dc.identifier.doi10.7547/17-063
dc.identifier.endpage290
dc.identifier.issn8750-7315
dc.identifier.issn1930-8264
dc.identifier.issue4
dc.identifier.scopusqualityQ3
dc.identifier.startpage282
dc.identifier.urihttp://doi.org/10.7547/17-063
dc.identifier.urihttps://hdl.handle.net/20.500.12511/4599
dc.identifier.volume109
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherAmerican Podiatric Medical Association
dc.relation.ispartofJournal of the American Podiatric Medical Associationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectHallucis Longus
dc.subjectDigitorum Longus
dc.subjectKnot
dc.subjectReconstruction
dc.subjectDysfunction
dc.subjectHarvest
dc.titleBiomechanical and morphometric properties of the long flexor tendons of the toes: A cadaver study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
Keskinbora, Mert-2019.pdf
Boyut:
687.47 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: