Effect of laboratory and chairside polishing methods on the surface topography of occlusal splint materials manufactured using conventional, subtractive and additive digital technologies

dc.authorid0000-0002-1753-6747
dc.authorid0000-0003-2861-9422
dc.authorid0009-0003-6320-3358
dc.contributor.authorBilir, Halenur
dc.contributor.authorEyyüpoğlu, Suzan Eda
dc.contributor.authorKaraman, Enes
dc.contributor.authorÖzcan, Mutlu
dc.contributor.authorLukic, Nenad
dc.date.accessioned2023-08-11T10:34:48Z
dc.date.available2023-08-11T10:34:48Z
dc.date.issued2023
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı
dc.description.abstractObjective: This study evaluated the polishing properties of the occlusal splint materials obtained using subtractive and additive manufacturing methods with the laboratory-type polishing (LP) and chairside-type polishing (CP) procedures. Material and Methods: Specimens (N=180, n=60 each group) were manufactured using one of the following methods: subtractive manufacturing method (SMM) (M-PM Disc, Merz Dental GmbH), additive manufacturing method (AMM) (Freeprint Splint 2.0, DETAX GmbH & Co. KG), and the conventional manufacturing method (CMM) (Promolux HC, Merz Dental GmbH). Following LP and CP procedures, surface roughness of the specimens was measured using a digital surface profilometer. One representative specimen was selected from each group, and a scanning electron microscope (SEM) image was made. Results: Both the manufacturing method and the polishing procedures significantly affected the results (P<0.01). Interaction terms were also significant (P[removed]
dc.description.abstractObjetivo: Este estudo avaliou as propriedades de polimento dos materiais de splint oclusal obtidos usando métodos de fabricação subtrativos e aditivos com os procedimentos de polimento laboratorial (LP) e polimento em consultório (CP). Material e Métodos: As amostras (N=180, n=60 para cada grupo) foram fabricadas usando um dos seguintes métodos: método de fabricação subtrativo (SMM) (M-PM Disc, Merz Dental GmbH), método de fabricação aditivo (AMM) (Freeprint Splint 2.0, DETAX GmbH & Co. KG) e o método de fabricação convencional (CMM) (Promolux HC, Merz Dental GmbH). Seguindo os procedimentos de LP e CP, a rugosidade da superfície dos espécimes foi medida usando um perfilômetro de superfície digital. Um espécime representativo foi selecionado de cada grupo, e uma imagem de microscópio eletrônico de varredura (SEM) foi obtida. Resultados: Tanto o método de fabricação quanto os procedimentos de polimento afetaram significativamente os resultados (P<0,01). Os termos de interação também foram significativos (P<0,001). Conclusão: Com ambos os métodos de polimento, a rugosidade superficial do grupo AMM foi a maior e a do grupo CMM a menor. Embora o procedimento CP tenha sido mais eficaz do que LP com ambos os métodos, a rugosidade da superfície ficou abaixo do limite de 0,2 ?m após ambos os procedimentos de polimento testados.
dc.identifier.citationBilir, H., Eyyüpoğlu, S. E., Karaman, E., Özcan, M. ve Lukic, N. (2023). Effect of laboratory and chairside polishing methods on the surface topography of occlusal splint materials manufactured using conventional, subtractive and additive digital technologies. Brazilian Dental Science, 26(3). https://dx.doi.org/10.4322/bds.2023.e3873
dc.identifier.doi10.4322/bds.2023.e3873
dc.identifier.issn2178-6011
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85165951280
dc.identifier.scopusqualityQ3
dc.identifier.urihttps://dx.doi.org/10.4322/bds.2023.e3873
dc.identifier.urihttps://hdl.handle.net/20.500.12511/11308
dc.identifier.volume26
dc.indekslendigikaynakScopus
dc.institutionauthorBilir, Halenur
dc.institutionauthorEyyüpoğlu, Suzan Eda
dc.institutionauthorKaraman, Enes
dc.language.isoen
dc.publisherUniversidade Estadual Paulista, Institute of Science and Technology of Sao Jose dos Campos
dc.relation.ispartofBrazilian Dental Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsAttribution 4.0 International*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectCAD-CAM
dc.subjectDental Materials
dc.subjectOcclusal Splints
dc.subjectPMMA
dc.subjectSurface Properties
dc.subjectCAD-CAM
dc.subjectMateriais Dentários
dc.subjectPMMA
dc.subjectPropriedades de Superfícies
dc.subjectSplints Oclusais
dc.titleEffect of laboratory and chairside polishing methods on the surface topography of occlusal splint materials manufactured using conventional, subtractive and additive digital technologies
dc.title.alternativeEfeito de métodos de polimento em laboratório e em consultório na topografia de superfície de materiais de splint oclusal fabricados usando tecnologias digitais convencionais, subtrativas e aditivas
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Bilir-Halenur-2023.pdf
Boyut:
1.02 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: