Effect of custom design insole applications with 3D modelling on baropodometric parameters in individuals with pes planus
| dc.authorid | 0000-0002-1447-5600 | |
| dc.authorid | 0000-0002-2452-1113 | |
| dc.authorid | 0000-0001-9804-368X | |
| dc.authorid | 0000-0002-6381-5982 | |
| dc.contributor.author | Aydoğan, Özgür | |
| dc.contributor.author | Yazıcı, Naile Hande | |
| dc.contributor.author | Tarakçı, Devrim | |
| dc.contributor.author | Atılgan, Esra | |
| dc.date.accessioned | 2023-12-13T10:14:32Z | |
| dc.date.available | 2023-12-13T10:14:32Z | |
| dc.date.issued | 2023 | |
| dc.department | İstanbul Medipol Üniversitesi, Sağlık Bilimleri Enstitüsü, Ortez ve Protez Ana Bilim Dalı | |
| dc.department | İstanbul Medipol Üniversitesi, Sağlık Bilimleri Fakültesi, Ergoterapi Bölümü | |
| dc.description.abstract | It was aimed to investigate the effect of custom made insoles on baropodometric analysis parameters in individuals with pes planus, using objective measurement and production methods. 100 individuals with pes planus, aged between 4-18 years in the study. Individuals who met the inclusion criteria and the medial longitudinal arch index were included in the study. Valgus angles of individuals, plantar measurements of the feet before the use of insoles and after 6 months of the use of insoles were evaluated with the Sensor Medica® device. When the measurement results of the ankle valgus angles of the individuals before and after the insoles were examined, it was observed that there was a statistical decrease in the mean results in both feet (p[removed]. | |
| dc.identifier.citation | Aydoğan, Ö., Yazıcı, N. H., Tarakçı, D. ve Atılgan, E. (2023). Effect of custom design insole applications with 3D modelling on baropodometric parameters in individuals with pes planus. International Journal of Disabilities Sports and Health Sciences, 6(3), 399-407. https://dx.doi.org/10.33438/IJDSHS.1309068 | |
| dc.identifier.doi | 10.33438/IJDSHS.1309068 | |
| dc.identifier.endpage | 407 | |
| dc.identifier.issn | 2645-9094 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-85177776925 | |
| dc.identifier.scopusquality | Q4 | |
| dc.identifier.startpage | 399 | |
| dc.identifier.uri | https://dx.doi.org/10.33438/IJDSHS.1309068 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12511/11988 | |
| dc.identifier.volume | 6 | |
| dc.indekslendigikaynak | Scopus | |
| dc.institutionauthor | Aydoğan, Özgür | |
| dc.institutionauthor | Yazıcı, Naile Hande | |
| dc.institutionauthor | Tarakçı, Devrim | |
| dc.institutionauthor | Atılgan, Esra | |
| dc.language.iso | en | |
| dc.publisher | Nevzat Demirci | |
| dc.relation.ispartof | International Journal of Disabilities Sports and Health Sciences | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | Attribution-ShareAlike 4.0 International | * |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | https://creativecommons.org/licenses/by-sa/4.0/ | * |
| dc.subject | 3D Design | |
| dc.subject | Foot | |
| dc.subject | Insole | |
| dc.subject | Pes Planus | |
| dc.subject | Plantar Pressure | |
| dc.title | Effect of custom design insole applications with 3D modelling on baropodometric parameters in individuals with pes planus | |
| dc.type | Article |