A microcontroller-based wireless multichannel neural data transmission system

dc.authorid0000-0003-1744-5252
dc.authorid0000-0001-9535-2102
dc.contributor.authorMukati, Muhammad Rizwan
dc.contributor.authorKocatürk, Samet
dc.contributor.authorKocatürk, Mehmet
dc.contributor.authorBaykaş, Tunçer
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:38:01Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:38:01Z
dc.date.issued2017
dc.departmentİstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik ve Elektronik Mühendisliği Bölümü
dc.departmentİstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Biyomedikal Mühendisliği Bölümü
dc.description.abstractChronically implantable microelectrode arrays enable multichannel electrophysiological recordings from the mammalian brains during behavioral experiments. Wireless data transmission systems combined with the microelectrode arrays and electrophysiology hardware allow the subjects to freely move during the neural recording sessions. In the present study, a microcontroller unit (MCU)-based wireless neural data transmission system is developed to collect data from behaving rats. The system achieves a data throughput up to 6.4 Mbps and enables recordings from 16 channel microelectrode arrays with a sampling rate of 25 KHz per channel. The present system offers a cost-effective and compact solution to perform multichannel in vivo electrophysiological recordings from behaving rats.
dc.identifier.citationMukati, M., Kocatürk, S., Kocatürk, M. ve Baykaş, T. (2017). A microcontroller-based wireless multichannel neural data transmission system. 21st National Biomedical Engineering Meeting (BIYOMUT). Istanbul, Turkey, November 24- December 26, 2017. https://dx.doi.org/10.1109/BIYOMUT.2017.8479160
dc.identifier.doi10.1109/BIYOMUT.2017.8479160
dc.identifier.isbn9781538653401
dc.identifier.scopusqualityN/A
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1519
dc.identifier.urihttps://dx.doi.org/10.1109/BIYOMUT.2017.8479160
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers
dc.relation.ecinfo:eu-repo/grantAgreement/TUBITAK/SOBAG/115E257
dc.relation.ispartof21st National Biomedical Engineering Meeting (BIYOMUT)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectAmplifiers
dc.subjectElectrophysiology
dc.subjectSpike Sorting
dc.titleA microcontroller-based wireless multichannel neural data transmission system