Alterations in biomechanical properties of the cornea among patients with polycystic kidney disease

dc.authorid0000-0003-0668-3749
dc.contributor.authorŞerefoğlu Çabuk, Kübra
dc.contributor.authorEsen, Bennur
dc.contributor.authorAtalay, Kürşat
dc.contributor.authorKırgız, Ahmet
dc.contributor.authorAydın, Rukiye
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:50:24Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:50:24Z
dc.date.issued2018
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalı
dc.descriptionWOS: 000439166500024
dc.descriptionPubMed ID: 28664236
dc.description.abstractThe aim of this study was to evaluate the corneal biomechanical features in polycystic kidney disease (PKD) patients and compare them with the healthy individuals. Totally 81 patients with a mean age of 48.46 +/- 14.51 years and 60 control cases with a mean age of 44.68 +/- 12.69 years were included in the study. All of the subjects underwent a complete ophthalmological examination, including visual acuity testing, biomicroscopic anterior and posterior segment examinations. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated intraocular pressure (IOPcc) were evaluated with the ocular response analyzer, and the central corneal thickness was evaluated with Sirius(A (R)) corneal topography. PKD patients had significantly increased CH values, without any alterations in IOP or CCT values, compared with the control cases (p:0.001). Among PKD patients, 23 were having liver cysts accompanying renal cysts. There was not any statistically significant difference between PKD patients with or without liver cysts regarding biomechanical properties of the cornea. However, both patient groups had statistically significantly increased CH values compared with the control cases. Patients with PKD present with higher CH values than age-matched controls. Larger studies are warranted to elucidate the alterations in corneal biomechanical properties and their clinical relevance in PKD patients.
dc.identifier.citationŞerefoğlu Çabuk, K., Esen, B., Atalay, K., Kırgız, A. ve Aydın, R. (2018). Alterations in biomechanical properties of the cornea among patients with polycystic kidney disease. International Ophthalmology, 38(4), 1559-1564. https://dx.doi.org/10.1007/s10792-017-0619-y
dc.identifier.doi10.1007/s10792-017-0619-y
dc.identifier.endpage1564
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.issue4
dc.identifier.scopusqualityQ2
dc.identifier.startpage1559
dc.identifier.urihttps://dx.doi.org/10.1007/s10792-017-0619-y
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1974
dc.identifier.volume38
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofInternational Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBiomechanics
dc.subjectCornea
dc.subjectPolycystic Kidney Disease
dc.titleAlterations in biomechanical properties of the cornea among patients with polycystic kidney disease
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Aydin, Rukiye(1).pdf
Boyut:
398.37 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text