Assessment of cochlear implant revision surgeries in a cohort of 802 patients

dc.authorid0000-0002-3887-4569
dc.contributor.authorKaramert, Recep
dc.contributor.authorDüzlü, Mehmet
dc.contributor.authorTutar, Hakan
dc.contributor.authorEravcı, Fakih Cihat
dc.contributor.authorTürkcan, Alper Kutalmış
dc.contributor.authorZorlu, Mehmet Ekrem
dc.contributor.authorUğur, Mehmet Birol
dc.contributor.authorCebeci, Süleyman
dc.contributor.authorBezgin, Selin Üstün
dc.contributor.authorCevizci, Raşit
dc.contributor.authorBayazıt, Yıldırım Ahmet
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:36:28Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:36:28Z
dc.date.issued2019
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı
dc.description.abstractObjective: To assess the etiology, demographics, rates and outcomes of revision surgeries, and device survival rates after cochlear implantation. Study Design: Retrospective case review. Setting: Tertiary Otology & Neurotology center. Patients: Cochlear implantees who received revision surgeries after implantation Interventions: Any surgical intervention, performed due to device failure or the major complications of cochlear implantation. Main Outcome Measure: Medical records of the patients who received cochlear implants (CIs) between July 2002 and March 2018 were reviewed retrospectively regarding postoperative complications. Demographic data, device survival rates, and causes of revisions were recorded. Results: Totally, 924 implantations were performed in 802 patients. Eighty one (8.7%) of them underwent 102 revision surgeries. The most common causes of revision surgeries were device failures and flap related problems which were seen in 28 and 18 patients, respectively. Overall CI survival rate was 91.9% in a 10 years period, which remained almost stable after 10 years. Although age was not found to be related with device failure (p = 0.693), device loss rates were significantly higher in adult implantees than children (p = 0.006). Conclusion: Device failure seems the most common cause of revision. The revision surgeries are usually safe and help to resolve the problem although flap problems are the most difficult to treat and may necessitate multiple revision surgeries. The device failure rate may reach to a plateau after 6 years. Overall CI survival rate exceeds 90% in 10 years period, and then remains stable.
dc.identifier.citationKaramert, R., Düzlü, M., Tutar, H., Eravcı, F. C., Türkcan, A. K., Zorlu, M. E. … Bayazıt, Y. A. (2019). Assessment of cochlear implant revision surgeries in a cohort of 802 patients. Otology & Neurotology, 40(4), 464-470. https://dx.doi.org/10.1097/MAO.0000000000002152
dc.identifier.doi10.1097/MAO.0000000000002152
dc.identifier.endpage470
dc.identifier.issn1537-4505
dc.identifier.issn1531-7129
dc.identifier.issue4
dc.identifier.scopusqualityQ1
dc.identifier.startpage464
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1170
dc.identifier.urihttps://dx.doi.org/10.1097/MAO.0000000000002152
dc.identifier.volume40
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherNLM (Medline)
dc.relation.ispartofOtology & Neurotologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCochlear Implant
dc.subjectCochlear Implant Complication
dc.subjectCochlear Implant Revision
dc.titleAssessment of cochlear implant revision surgeries in a cohort of 802 patients
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
beyazıt, yıldırım ahmet.pdf
Boyut:
325.82 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text