Effect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCT

dc.authorid0000-0003-3468-7712
dc.authorid0000-0002-8084-7855
dc.contributor.authorBaşkan, Özdil
dc.contributor.authorErol, Cengiz
dc.contributor.authorÖzbek, Hanefí
dc.contributor.authorPaksoy, Yahya
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:57:20Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:57:20Z
dc.date.issued2015
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalı
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Tıbbi Farmakoloji Ana Bilim Dalı
dc.descriptionWOS: 000354950100028
dc.descriptionPubMed ID: 26103494
dc.description.abstractThe purpose of our study was to investigate the effect of iterative reconstruction (IR) as a dose reduction system on the image quality (IQ) of the adult head computed tomography (CT) at various low-dose levels, and to identify ways of setting the amount of dose reduction. We performed two noncontrast low-dose (LD) adult head CT protocols modified by lowering the tube current with IR which were decided in the light of a group of phantom studies. Two groups of patients, each 100 underwent noncontrast head CT with LD-I and LD-II, respectively. These groups were compared with 100 consecutive standard dose (STD) adult head CT protocol in terms of quantitative and qualitative IQ. The signal-to-noise ratio (SNR) of the white matter (WM) and gray matter (GM) and contrast-to-noise ratio (CNR) values in the LD groups were higher than the STD group. The differences were statistically significant. When the STD and the LD groups were compared qualitatively, no significant differences were found in overall quality. By selecting the appropriate level of IR 34%, radiation dose reduction in adult head CT can be achieved without compromising IQ.
dc.identifier.citationBaşkan, Ö., Erol, C., Özbek, H. ve Paksoy, Y. (2015). Effect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCT. Journal of Applied Clinical Medical Physics, 16(3), 285-296. https://dx.doi.org/10.1120/jacmp.v16i3.5360
dc.identifier.doi10.1120/jacmp.v16i3.5360
dc.identifier.endpage296
dc.identifier.issn1526-9914
dc.identifier.issue3
dc.identifier.scopusqualityQ1
dc.identifier.startpage285
dc.identifier.urihttps://dx.doi.org/10.1120/jacmp.v16i3.5360
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2952
dc.identifier.volume16
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherMultimed
dc.relation.ispartofJournal of Applied Clinical Medical Physicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectImage Quality
dc.subjectDose Reduction
dc.subjectReconstruction Methods
dc.subjectPhantom Studies
dc.subjectMDCT
dc.titleEffect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCT