Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Kara, Deniz" seçeneğine göre listele

Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    A new mini-external fixator for treating hallux valgus: A preclinical, biomechanical study
    (Elsevier Science Inc, 2016) Erdil, Mehmet; Ceylan, Hasan Hüseyin; Polat, Gökhan; Kara, Deniz; Bozdağ, Ergün; Sünbüloğlu, Emin
    Proximal metatarsal osteotomy is the most effective technique for correcting hallux valgus deformities, especially in metatarsus primus varus. However, these surgeries are technically demanding and prone to complications, such as nonunion, implant failure, and unexpected extension of the osteotomy to the tarsometatarsal joint. In a preclinical study, we evaluated the biomechanical properties of the fixator and compared it with compression screws for treating hallux valgus with a proximal metatarsal osteotomy. Of 18 metatarsal composite bone models proximally osteotomized, 9 were fixed with a headless compression screw and 9 with the mini-external fixator. A dorsal angulation of 10 degrees and displacement of 10 mm were defined as the failure threshold values. Construct stiffness and the amount of interfragmentary angulation were calculated at various load cycles. All screw models failed before completing 1000 load cycles. In the fixator group, only 2 of 9 models (22.2%) failed before 1000 cycles, both between the 600th and 700th load cycles. The stability of fixation differed significantly between the groups (p < .001). The stability provided by the mini-external fixator was superior to that of compression screw fixation. Additional testing of the fixator is indicated.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Does intra-articular fracture change the lubricant content of synovial fluid?
    (BioMed Central, 2015) Ceylan, Hasan Hüseyin; Erdil, Mehmet Emin; Polat, Gökhan; Kara, Deniz; Kılıç, Elif; Koçyi?it, Abdurrahim; Tuncay, İbrahim
    Background: Lubrication function is impaired and the lubricant content of synovial fluid (SF) changes immediately after plateau tibia fractures. Here, we aimed to analyze the lubricant content of SF at chronic term following plateau tibia fracture. Methods: Forty-eight surgically treated patients without joint incongruency (<2 mm displacement) were included in the study. Joint aspiration had been possible in 16 of the participants. However, sampling could be made from healthy knees in only ten of these patients. Twenty-six SF samples (16 injured knees, 10 healthy knees) were analyzed for concentrations of hyaluronic acid (HA), proteoglycan-4 (PRG4), TNF-alpha, IL-1 beta, and IL-6. Results: The group of experimental samples were obtained at a mean of 31 (12-66) months after injury from patients with a mean age of 45.1 (32-57) years. There were no relationships detected between biochemical analysis results and patient ages, sexes, postoperative time, and fracture type. After excluding six patients for whom we could not sample from their healthy knee, ten patients' values were compared with paired Wilcoxon signed rank test and no significant differences detected between the healthy and injured knee in terms of the SF concentrations of HA and PRG4 (p = 0.225 and 0.893, respectively). Similarly, there were no statistically significant differences in SF sample concentrations of TNF-alpha, IL-1 beta, and IL-6 between healthy and injured knees. Conclusions: Despite acute changes, the long-term concentrations of HA and PRG4 were similar after plateau tibial fracture. We could not detect any concentration level differences between healthy knees and injured knees regarding HA and PRG4 in the long-term follow-up.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Ipsilateral olecranon and distal radius fracture: A case report
    (Elsevier, 2015) Cengiz, Ömer; Polat, Gökhan; Karademir, Gökhan; Kara, Deniz; Erdil, Mehmet
    INTRODUCTION: Concomitant ipsilateral olecranon and distal radius fracture are rare injuries. Their clinical presentation is unusual and investigation and management is poorly described. PRESENTATION OF CASE: We present a 55-year-old woman patient who fell off sustaining a concomitant distal radius and olecranon fracture in the same extremity. On examination, there was gross swelling of the proximal and distal forearm and no neurovascular deficit. Radiographs confirmed distal radius and olecranon fracture. Patient was treated with open reduction and anatomic locking plate for olecranon and a closed reduction percuteneous K wire fixation with penning fixator for distal radius fracture. After physical therapy program, functional results were good and DASH score was 60. DISCUSSION: Several different combinations of fracture with dislocation have been described, but, to our knowledge, concurrent ipsilateral olecranon and distal radius fracture has not been reported before. In the literature review there are two similar cases in the English literature. CONCLUSION: Ipsilateral olecranon and distal radius fracture is a very rare injury due to different trauma mechanisms. However we should keep in mind that there may be adjacent joints and structures for concomitant injuries.

| İstanbul Medipol Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kavacık, Göztepe Mah, Atatürk Cd. No:40, 34810 Beykoz, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim