Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Egemen, Emrah" seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Interdural hematomas: An update of literature
    (Edizioni Minerva Medica, 2017) Genç, Ali; Yılmaz, Muhammet Bahadır; Egemen, Emrah; Yılmaz, Mehmet; Sav, Aydın
    Interdural hematoma (IDH) is an extremely rare entity. To our knowledge, to date, only 6 cases of in hemorrhage, aneurysm rupture, intrauterine asphyxia, and mechanical injury.1-6 Interdural hematomas can be misdiagnosed as extradural hematoma (EDH) because of their similar clinical presentation and radiologic features.1 The clinical data of these six cases are displayed in Table Iterdural hematomas have been reported with varying etiologies, such as iatrogenic.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Lumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: A retrospective clinical and radiological analysis of 71 patients
    (Korean Orthopaedic Association, 2017) Özer, Ali Fahir; Öktenoğlu, Tunç; Egemen, Emrah; Sasani, Mehdi; Yılmaz, Atilla; Erbulut, Deniz Ufuk; Yaman, Onur; Süzer, Tuncer
    Background: This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. Methods: A total of 71 patients underwent single-level posterior transpedicular dynamic stabilization between 2011 and 2014 due to lumbar degenerative disc disease. Three different dynamic systems used include: (1) the Dynesys system; (2) a dynamic screw with a PEEK rod; and (3) a full dynamic system (a dynamic screw with a dynamic rod; BalanC). The mean patient age was 45.8 years. The mean follow-up was 29.7 months. Clinical and radiological data were obtained for each patient preoperatively and at 6, 12, and 24 months of follow-up. Results: Clinical outcomes were significantly improved in all patients. There were no significant differences in the radiological outcomes among the groups divided according to the system used. Screw loosening was detected in 2 patients, and 1 patient developed screw breakage. All patients with screw loosening or breakage underwent revision surgery. Conclusions: Each procedure offered satisfactory outcome regardless of which system was applied.

| İstanbul Medipol Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kavacık, Göztepe Mah, Atatürk Cd. No:40, 34810 Beykoz, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim