Yazar "Ece, Dilek" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Endobronchial ultrasound-guided transbronchial fine needle aspiration: Determinants of adequacy(Bayçınar Medical Publishing, 2018) Ece, Dilek; Hallaç Keser, Sevinç; Ça?layan, Benan; Salepçı, Banu Musaffa; Babür Güler, Gamze; Şensu, Sibel; Geçmen, Gonca Gül; Çoban Kökten, ŞerminBackground: This study aims to evaluate the factors influencing the adequacy of endobronchial ultrasound-guided transbronchial fine needle aspiration specimens. Methods: A retrospective analysis of 1,700 endobronchial ultrasound-guided transbronchial fine needle aspiration samples obtained from 822 patients (500 males, 322 females; mean age 56 +/- 13 years; range 16 to 83 years) was performed between March 2011 and March 2014 at our center. Variables potentially associated with sampling adequacy, such as all cytological materials and procedure notes (lymph node and/or lesion size, localization, needle pass number, and slide number) were examined. Results: The overall specimen adequacy was 79.8%. The specimen adequacy was associated with needle pass number (P <= 0.001). Adequacy rate was 66.9% for one needle pass and 85.8% for three needle passes. According to the sampling regions, adequacy rates showed a difference [69.2%-85.8%; (p <= 0.005)]. In the multivariate logistic regression analysis of subcarinal (7) lymph node station, patient age (odds ratio, 0.983; 95% confidence interval, 0.966-1.000; p=0.049) and number of slides (odds ratio, 1.240; 95% confidence interval, 1.062-1.448; p=0.006) were independent determining factors of specimen adequacy. While independent determinants of specimen adequacy for the right paratracheal (4R) region were lymph node size (odds ratio, 1.486; 95% confidence interval, 0.973-2.268; p=0.067) and number of slides (odds ratio, 1.418; 95% confidence interval, 1.146-1.756; p=0.001), they were lymph node size (odds ratio, 1.594; 95% confidence interval, 0.960-2.645; p=0.071) and number of needle passes (odds ratio, 2.277; 95% confidence interval, 1.360-3.811; p=0.002) for the right interlobar (11R) region. Independent determinant of specimen adequacy for the left paratracheal (4L) lymph node station was the number of needle passes (odds ratio, 1.656; 95% confidence interval, 0.955-2.869; p=0.072). Conclusion: During endobronchial ultrasound-guided transbronchial fine needle aspirations, particularly when rapid on site evaluation cannot be applied, consideration of factors affecting adequacy according to lymph node localizations may increase the chance for obtaining materials with suitable quality for cytologic evaluation.Öğe Review of hydatid cyst with focus on cases with unusual locations(De Gruyter Poland Sp Zoo, 2017) Hallaç Keser, Sevinç; Selek, Ayşegül; Ece, Dilek; Barışık, Cem Cahit; Şensu, Sibel; Geçmen, Gonca Gül; Şengiz Erhan, Selma; Çoban Kökten, Şermin; Özdemir Barışık, Nagehan; Ege Gül, AylinObjective: This study has been conducted so as to contribute to health statistics of hydatid cyst by the data obtained from our clinic, and to discuss hydatid cysts in unusual locations. Material and Method: Cases diagnosed as hydatid cyst at Dr. Lutfi Kirdar Kartal Research and Education Hospital Pathology Clinic between 2007 and 2015 have been evaluated based on criteria such as age, sex and location. Results: A total of 364 cases, 209 females and 155 males, have been included in the study. The subjects in the cases are aged between 4 and 81 (mean: 38.84). Regarding the sites, 254 (69.8%) of the cases are located in liver, and 53 (14.6%) in the lung. Fifty-seven cases (15.6%) have been detected in unusual sites other than the lung or liver. The rate of isolated organ involvement, other than the lung and liver, has been found to be 10.3%. Conclusion: Since hydatid cyst can be found in all the body sites, it should be taken into account in the differential diagnosis of all cystic lesions.











