Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Demir, Becen" seçeneğine göre listele

Listeleniyor 1 - 5 / 5
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Cleaning efficacy of poly-ether-ether-ketone tips in eliminating cement remnants around implants with different abutment heights
    (Allen Press Inc, 2020) Koyuncuoğlu, Cenker Zeki; Kara, Haluk Barış; Akdemir, Sinan; Demir, Becen; Husain, Nadin Al-Haj; Özcan, Mutlu
    The excess cement not removed after the cementation of fixed implant-supported restorations may cause loss of peri-implant attachment or adjacent bone. The aims of this study were to evaluate the amount of residual cement at different abutment-crown connection levels and to test the cleaning efficacy of poly-ether-ether-ketone (PEEK) ultrasonic tips after cementation. One implant was placed in an anterior central tooth position 5 mm below the gingival margin in an acrylic model, and 32 stone models were obtained with implant analogs. Abutment heights of 1-2 and 2.5-4 mm were used on the vestibular and lingual sides, respectively. Crowns were cemented and cleaned, and half of the samples were cleaned again using PEEK tips. The abutment-crown suprastructure was then disconnected, and cleaning efficacy was evaluated. Varying amounts of excess cement were found on all specimens except for the PEEK group with abutment-crown connections 1 mm below the gingival margin. An increase of undetected cement remnants was observed when the restoration margins were located deeper subgingivally. Various amounts of excess cement associated with margin location were detected on the abutment-restoration complex despite meticulous cleaning efforts. Ultrasonic PEEK tips were effective at cleaning the cement remnants around implants to a certain depth.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Effect of prophylactic polishing protocols and mouthrinses on the surface roughness of different adhesive restorative materials
    (2016) Toz Akalın, Tuğba; Demir, Becen; Öztürk Bozkurt, Funda; Gözükara Bağ, Harika; Tuncer, Safa
    Aim: The aim of this study was to evaluate the effects of prophylactic polishing protocols and mouth rinses on surface roughness of different tooth colored restoratives that were generally preferred for Class V cavities.Materials and Methods: A reinforced conventional glass ionomer, a resin modified glass ionomer, a flowable, and a nanohybrid composite were used. Forty specimens for each restorative materials were fabricated and polished and baseline surface roughness (Ra) measurements were obtained by a profilometer. Then the specimens were divided into two groups according to prophylactic polishing pro-tocols: ultrasonic scaling or ultrasonic scaling and air polishing. Following Ra measurements prophy-lactic polishing protocols groups were divided into two subgroups for two different mouth rinses im-mersion and Ra measurements were obtained afterwards. Finally the specimens were re-polished and Ra values were recorded. Results: Prophylactic polishing protocols, especially air polishing, resulted in significant increases in surface roughness (p<0.001) while mouth rinses had minimal effects (p>0.05). Re-polishing proce-dures decreased surface roughness values. Tested glass ionomers showed worse surface roughness values compared with resin composites. Conclusion: Result of this research indicated that prophylactic polishing protocols increased surface roughness values of restorative materials, especially glass ionomers.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Interdisciplinary treatment of a patient with bilateral cleft lip and palate and congenitally missing and transposed teeth
    (Elsevier, 2014) Germeç Çakan, Derya; Canter, Halil İbrahim; Çakan, Umut; Demir, Becen
    The comprehensive treatment of a patient with cleft lip and palate requires an interdisciplinary approach for functional and esthetic outcomes. A 20-year-old woman with bilateral cleft lip and palate had a chief complaint of unesthetic appearance of her teeth and the presence of oronasal fistulae. Her clinical and radiographic evaluation showed a dolichofacial growth pattern, a Class II skeletal relationship with retroclined maxillary central incisors, 5 mm of negative overjet, maxillary constriction, maxillary and mandibular crowding, congenitally missing maxillary right incisors and left lateral incisor, and a transposed maxillary left canine. Her treatment plan included the extraction of 3 premolars, maxillary expansion, segmental maxillary osteotomy, repair of the oronasal fistulae, rhinoplasty, periodontal surgery, and prosthodontic rehabilitation. To obtain a better occlusion and reduce the dimensions of the fistulae, orthognathic surgery comprising linear and rotational movements of the maxillary segments (premaxilla, right and left maxillary alveolar segments) in all 3 axes was planned by performing 3-dimensional virtual surgery on 3-dimensional computerized tomography. At the end of the interdisciplinary treatment, a functional occlusion, a harmonious profile, and patient satisfaction were achieved. Posttreatment records after 1 year showed stable results.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Periodontal sağlığın in vitro fertilizasyon sonuçları üzerine etkisinin değerlendirilmesi
    (Afyonkarahisar Sağlık Bilimleri Üniversitesi, 2020) Altaş, Nurcan; Uslu Toygar, Hilal; Cilasun, Ülkem; Kumbak Aygün, Banu; Demir, Becen
    AMAÇ: Bu çalışmanın amacı sistemik sağlık üzerinde et-kisi kanıtlanmış olan periodontal durumun infertil kadın-larda uygulanan in vitro fertilizasyon tedavisi sonuçları üzerindeki etkisini değerlendirmektir. GEREÇ VE YÖNTEM: İnfertilite tanısı konmuş kadın has-talardan sosyodemografik veriler bir anket yardımıyla toplanmıştır. Kan testi gününde plak indeksi, gingival indeks, cep derinliği, sondalamada kanama indeksi öl-çümleri yapılmıştır. Buna göre; sağlıklı, gingivitisli ve pe-riodontitisli olarak sınıflandırılan hastalar ile kullanılan human chorionic hormon gonadotropin (hCG) dozu, öst-radiol ve progesteron seviyeleri, transfer edilen embriyo sayıları, oosit sayıları ve gebelik sonuçları karşılaştırılmış-tır. Çalışmada, tek yönlü ANOVA, Tukey HDS, Tampane’s T2, Kruskal-Wallis, Mann-Whitney U ve ki-kare testleri kullanılmıştır. BULGULAR: Gruplar arasında oosit sayıları, transfer edi-len embriyo sayıları ve gebelik sonuçları açısından bir farklılık gözlenmemiştir. Gruplar arasında hCG günü öst-radiol seviyesi açısından bir farklılık gözlenmemesine karşın hCG günü progesteron seviyesi periodontitis gru-bunda sağlıklı ve gingivitisli gruba göre anlamlı şekilde yüksek bulunmuştur. SONUÇ:Periodontitis grubunda gözlenen progesteron seviyesindeki yükselme IVF sonucunu etkileyebilecek olan eşik değerin altındadır. Periodontal durumun inferti-lite tedavisi üzerindeki etki mekanizmasının belirlenmesi için geniş ölçekli ve uzun vadeli çalışmalara ihtiyaç duyul-maktadır.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Short-term radio frequency analysis measurements of adin implants
    (Hacettepe University, 2017) Demir, Becen; Balcı, Nur; Kara, Haluk Barış; Çakan, Umut; Uslu Toygar, Hilal
    Background and Aim: The purpose of this study was to understand and monitor the transition from primary to secondary stability of implants having sand blast large grit acid etched surface, for the timing of the prosthodontic treatment via using the Radio Frequency Analysis. Subjects and Methods: Forty-two dental implants were placed in 19 patients and Implant Stability Quotient measurements were performed at baseline, 1st, 2nd, 3rd, 4th, 6th and 8th weeks. The lengths and diameters of the implants were also correlated with Implant Stability Quotient values. Results: The present data showed no correlation between lengths, diameters and Radio Frequency Analysis at any of the measurement times. In each group, implant stability at the baseline and 8th weeks showed significant higher Radio Frequency Analysis (RFA) values than the 2nd, 3rd and 4th weeks (p<0.05). Statistically no difference was found between the baseline and 8th week measurements (p>0.05).Conclusion: Measuring Implant Stability Quotient values can help the clinician understand the condition of the implant without disrupting the healing implant-bone interface, allowing to decide the loading time.

| İstanbul Medipol Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kavacık, Göztepe Mah, Atatürk Cd. No:40, 34810 Beykoz, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim