Basit öğe kaydını göster

dc.contributor.authorBilir, Halenur
dc.contributor.authorYüzbaşıoğlu, Emir
dc.contributor.authorSayar, Gülşilay
dc.contributor.authorKılınç, Delal Dara
dc.contributor.authorGözükara Bağ, Harika Gözde
dc.contributor.authorÖzcan, Mutlu
dc.date.accessioned2022-11-16T07:12:45Z
dc.date.available2022-11-16T07:12:45Z
dc.date.issued2022en_US
dc.identifier.citationBilir, H., Yüzbaşıoğlu, E., Sayar, G., Kılınç, D. D., Gözükara Bağ, H. G. ve Özcan, M. (2022). CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: Up to 40 months clinical results of a randomized-controlled pilot study. Journal of Esthetic and Restorative Dentistry, 34(7), 1122-1131. https://doi.org/10.1111/jerd.12945en_US
dc.identifier.issn1496-4155
dc.identifier.issn1708-8240
dc.identifier.urihttps://doi.org/10.1111/jerd.12945
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9968
dc.description.abstractPurpose This pilot study was part of a larger study planned for the future which aimed to compare the clinical success of two different resin cements used in the cementation of CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed dentures (RBFPDs). Methods Twenty-four RBFPDs were fabricated with monolithic zirconia (Katana (TM) Zirconia HT, Kuraray Noritake Dental Inc, Tokyo, Japan). Panavia F2.0 (PF2.0; n = 12) and Panavia V5 (PV5; n = 12) were used for cementation. The survival period was defined as the time when the restoration was placed in the mouth and lasted until an irreparable damage occurred. The repairable failures were identified as relative and irreparable failures were identified as absolute failure. The survival rate of the RBFPDs was determined by the Kaplan-Meier estimator. Statistical significance was set at p < 0.05. Results The mean observation times of the PF2.0 group and the PV5 group were 40.45 +/- 6.15 months and 40.18 +/- 6.41 months, respectively. Four failures occurred in the PF2.0 group. No failure was observed in the PV5 group. The curves of survival rate (PF2.0 = 80%, PV5 = 100%) showed no statistically significant difference (p = 0.031), although success rate (PF2.0 = 66.7%, PV5 = 100%) showed statistically significant difference (p = 0.317). Conclusion Up to 40 months mean follow-up period, performance of RBFPDs bonded with PV5 was better than with PF2.0. Clinical Significance For clinicians, it is a matter of hesitation to apply single-retainer RBFPDs. This study contains results of 40 months (minimum 32, maximum 50.47 months) clinical follow-ups of single-retainer RBFPDs. These results will enlighten clinicians about the clinical success of the resin cement type for single-retainer monolithic zirconia ceramic RBFPDs.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectCAD/CAMen_US
dc.subjectCeramicsen_US
dc.subjectDental Materialsen_US
dc.subjectDigital Dentistryen_US
dc.subjectProsthodonticsen_US
dc.titleCAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: Up to 40 months clinical results of a randomized-controlled pilot studyen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Esthetic and Restorative Dentistryen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalıen_US
dc.authorid0000-0002-1753-6747en_US
dc.identifier.volume34en_US
dc.identifier.issue7en_US
dc.identifier.startpage1122en_US
dc.identifier.endpage1131en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1111/jerd.12945en_US
dc.institutionauthorBilir, Halenur
dc.identifier.wosqualityQ2en_US
dc.identifier.wos000835866300001en_US
dc.identifier.scopus2-s2.0-85135233359en_US
dc.identifier.pmid35920051en_US
dc.identifier.scopusqualityQ1en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster