• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   [email protected]
  • Fakülteler
  • Tıp Fakültesi
  • Bildiri Koleksiyonu
  • View Item
  •   [email protected]
  • Fakülteler
  • Tıp Fakültesi
  • Bildiri Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effect of depth and control point number for MLC transmission and dosimetric leaf gap

Thumbnail

View/Open

Tam Metin / Full Text (368.1Kb)

Access

info:eu-repo/semantics/openAccess

Date

2015

Author

Küçükmorkoç, Esra
Doyuran, Mine
Çağlar, Mustafa
Küçük, Nadir
Acar, Hilal
Altınok, Ayşe
Çağlar, Hale

Metadata

Show full item record

Citation

Küçükmorkoç, E., Doyuran, M., Çağlar, M., Küçük, N., Acar, H., Altınok, A. ... Çağlar, H. (2015). The effect of depth and control point number for MLC transmission and dosimetric leaf gap. Radiotherapy and Oncology içinde (S763-S764 ss.). https://doi.org/10.1016/S0167-8140(15)41406-9

Abstract

Purpose/Objective: MLC transmision (MLCT) and dosimetric leaf gap (DLG) in Treatment Planning System (TPS) are important parameters for dose calculation and they provide accuracy of delivering IMRT plans. MLCT and DLG account the leakage of MLC and the effect of rounded leaf ends, respectively. The aim of this study is to examine control point (CP) and depth dependance for MLCT and DLG. Materials and Methods: MLCT and DLG parameters were measured with PTW 0.125 cc semi-flex ionization chember in a solid water phantom for Varian Trilogy machine with Millenium MLC. MLCT measurements were obtained 15x15cm2 field size at different depths (Dmax,5,10 and 15cm) for 6 MV photon beam. To derive the DLG measurement , a series of Sliding Window (SW) fields of 2,4,7,10,15 and 20 mm gap widths were used. These SW fields were prepared with different number of CP (2,3,5,7,9,11,13,16 and 21) and DLG measuremets were performed at same depths and field size. DLG values were calculated for each depth using MLCT parameters which were measured at same depth.

WoS Q Kategorisi

Q1

Source

Radiotherapy and Oncology

Volume

115

Issue

Supplement: 1

URI

https://hdl.handle.net/20.500.12511/9303

Collections

  • Bildiri Koleksiyonu [480]
  • WoS İndeksli Yayınlar Koleksiyonu [5546]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Guide | Contact |

[email protected]

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess TypeThis CollectionBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess Type

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide || Library || İstanbul Medipol University || OAI-PMH ||

Kütüphane ve Dokümantasyon Daire Başkanlığı, İstabul, Turkey
If you find any errors in content, please contact: [email protected]

Creative Commons License
[email protected] by İstanbul Medipol University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

[email protected]:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.