dc.contributor.author | Sayın Özel, Gülsüm | |
dc.contributor.author | İnan, Özgür | |
dc.contributor.author | Seçilmiş Acar, Aslı | |
dc.contributor.author | Alnıaçık İyidoğan, Gamze | |
dc.contributor.author | Dolanmaz, Doğan | |
dc.contributor.author | Yıldırım, Gülsün | |
dc.date.accessioned | 2022-03-17T07:36:06Z | |
dc.date.available | 2022-03-17T07:36:06Z | |
dc.date.issued | 2021 | en_US |
dc.identifier.citation | Sayın Özel, G., İnan, Ö., Seçilmiş Acar, A., Alnıaçık İyidoğan, G., Dolanmaz, D. ve Yıldırım, G. (2021). Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period. Journal of Dental Research, Dental Clinics, Dental Prospects, 15(4), 226-231. https://doi.org/10.34172/joddd.2021.037 | en_US |
dc.identifier.issn | 2008-210X | |
dc.identifier.issn | 2008-2118 | |
dc.identifier.uri | https://doi.org/10.34172/joddd.2021.037 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12511/9134 | |
dc.description.abstract | Background. The surface properties of implants are effective factors for increasing the osseointegration and activity of osteoprogenitor cells. This study compared the stability of dental implants with sandblasted and acid-etched (SLA) and modified surfaces (SLActive) using the resonance frequency analysis (RFA). Methods. In a split-mouth design, 50 dental implants with either SLA surface properties (n = 25) or modified (SLActive) surface properties (n = 25) were placed in the mandibles of 12 patients with a bilateral posterior edentulous area. Implant stability was measured using RFA (Osstell) at implant placement time and every week for 1, 2, and 3 months before the conventional loading time. Results. One week following the implantation, implant stability increased from 70 to 77.67 for SLA and from 71.67 to 79 for SLActive (P [removed] 0.05). Conclusions. For both implant surfaces, increased stability was observed over time, with no significant differences between the groups. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Tabriz University of Medical Sciences | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Attribution 4.0 International | * |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | * |
dc.subject | Bone-Implant Interface | en_US |
dc.subject | Dental Implants | en_US |
dc.subject | Osseointegration | en_US |
dc.subject | Resonance Frequency Analysis | en_US |
dc.subject | SLA | en_US |
dc.subject | SLActive | en_US |
dc.title | Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period | en_US |
dc.type | article | en_US |
dc.relation.ispartof | Journal of Dental Research, Dental Clinics, Dental Prospects | en_US |
dc.department | İstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı | en_US |
dc.authorid | 0000-0001-8833-5259 | en_US |
dc.identifier.volume | 15 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 226 | en_US |
dc.identifier.endpage | 231 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.34172/joddd.2021.037 | en_US |
dc.institutionauthor | Sayın Özel, Gülsüm | |
dc.identifier.scopus | 2-s2.0-85125638571 | en_US |
dc.identifier.pmid | 35070174 | en_US |
dc.identifier.scopusquality | Q4 | en_US |