dc.contributor.author | Güzelburç, Vahit | |
dc.contributor.author | Soytaş, Mustafa | |
dc.contributor.author | Kiremit, Murat Can | |
dc.contributor.author | Erkurt, Bülent | |
dc.contributor.author | Altay, Bülent | |
dc.contributor.author | Darçın, Kamil | |
dc.contributor.author | Akbulut, Ziya | |
dc.contributor.author | Albayrak, Selami | |
dc.date.accessioned | 2022-03-03T07:54:48Z | |
dc.date.available | 2022-03-03T07:54:48Z | |
dc.date.issued | 2020 | en_US |
dc.identifier.citation | Güzelburç, V., Soytaş, M., Kiremit, M. C. ve Erkurt, B., Altay, B., Darçın, K. ... Albayrak, S. (2020). Retrograd intrarenal cerrahi esnasında oluşan vücut sıcaklık değişikliklerini etkileyen faktörler. Yeni Üroloji Dergisi, 15(3), 207-213. https://doi.org/10.33719/yud.685177 | en_US |
dc.identifier.issn | 1305-2489 | |
dc.identifier.uri | https://doi.org/10.33719/yud.685177 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12511/9082 | |
dc.description.abstract | Amaç: Retrograd intrarenal cerrahi (RIRC)
esnasında diğer endoürolojik operasyonlardan
farklı olarak daha düşük debi ve hacimde irrigasyon sıvısı kullanılmaktadır. Çalışmamızda
kullanılan irrigasyon sıvısına bağlı olarak vücutta oluşan sıcaklık değişiklikleri ve buna etki eden
faktörler incelendi.
Gereç ve Yöntemler: Prospektif olarak çalışmaya 128 hasta dahil edildi. Operasyonlarda standart olarak 21°C ameliyathane odasında bulundurulan izotonik irrigasyon sıvısı kullanıldı. Hiçbir
hastaya aktif ısıtma uygulanmadı. Hastaların ateşi
anestezi indüksiyonu öncesinde ve uyandırma öncesinde periferik yoldan ölçüldü. Ölçülen vücut
sıcaklık farklarının hasta özellikleri, operasyon
süresi, kullanılan irrigasyon sıvısı hacmi ve taş büyüklüğüyle ilişkisi değerlendirildi.
Bulgular: Operasyona girişte timpanik ortalama vücut sıcaklığı 36,3±0,35°C iken operasyon sonunda 35,8±0,5°C hesaplandı. Hastaların
102’sinde (%79,7) post-op vücut sıcaklık düşüşü
(0,67±0,47°C) kaydedildi. Operasyon öncesi ve
sonrasındaki vücut sıcaklık değerleri karşılaştırıldığında anlamlı düşüş saptandı (p<0,0001). Bu
düşüş ile hasta ve operatif veriler arasında istatistiksel anlamlı bir ilişki saptanmadı.
Sonuç: RIRC sonrasında vücut sıcaklığı düşmektedir ancak ameliyathane oda sıcaklığı dışındaki hasta ve operatif verilerle ateş değişimi arasında ilişki kurulamamıştır. | en_US |
dc.description.abstract | Objective: When compared to other endourologic operations, irrigation fluid with lower flow
rate and volume is used during retrograde intrarenal surgery (RIRS). In our study, body temperature changes occurring due to irrigation fluid and
factors affecting these were assessed.
Material and Methods: One hundred and
twenty-eight patients were prospectively included
in the study. During operations, a standart izotonic irrigation fluid kept in the operating room at 21
°C was used. Active heating was not applied to any
patient. Body temperature of patients was measured peripherally before anesthesia induction
and before recovery. Relationship of body temperature differences with patient characteristics,
operation time, irrigation fluid volüme and stone
size was evaluated.
Results: Mean tympanic body temperature
was 36,3±0,35°C at the start of operation and
35,8±0,5°C at the end. Post-operative fall in body
temperature (0,67±0,47°C) was recorded in 102
patients (79.7%). When body tempertaure values
before and after the operation were compared, a
significant reduction was found (p<0,0001). No
statistically significant correlation was obtained
between this reduction and patient and operative
data.
Conclusion: Body temperature falls after
RIRC however, no relation was found between
temperature change and patient and operative
data other than operating room temperature. | en_US |
dc.language.iso | tur | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Attribution-NonCommercial 4.0 International | * |
dc.rights.uri | https://creativecommons.org/licenses/by-nc/4.0/ | * |
dc.subject | İntraoperatif Hipotermi | en_US |
dc.subject | İrrigasyon Sıvıları | en_US |
dc.subject | Retrograd Intrarenal Cerrahi | en_US |
dc.subject | Termoregülasyon | en_US |
dc.subject | Intraoperative Hypothermia | en_US |
dc.subject | Irrigation Solution | en_US |
dc.subject | Retrograde Intrarenal Surgery | en_US |
dc.subject | Thermoregulation | en_US |
dc.title | Retrograd intrarenal cerrahi esnasında oluşan vücut sıcaklık değişikliklerini etkileyen faktörler | en_US |
dc.title.alternative | The factors affecting body temperature changes during retograde intrarenal surgery | en_US |
dc.type | article | en_US |
dc.relation.ispartof | Yeni Üroloji Dergisi | en_US |
dc.department | İstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Anesteziyoloji ve Reanimasyon Ana Bilim Dalı | en_US |
dc.department | İstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Üroloji Ana Bilim Dalı | en_US |
dc.authorid | 0000-0001-9988-2944 | en_US |
dc.authorid | 0000-0002-3474-3510 | en_US |
dc.authorid | 0000-0002-6676-9205 | en_US |
dc.authorid | 0000-0003-3415-1475 | en_US |
dc.authorid | 0000-0001-8864-5441 | en_US |
dc.authorid | 0000-0002-0004-8392 | en_US |
dc.authorid | 0000-0001-7146-4767 | en_US |
dc.authorid | 0000-0002-4245-7506 | en_US |
dc.identifier.volume | 15 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 207 | en_US |
dc.identifier.endpage | 213 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.33719/yud.685177 | en_US |
dc.institutionauthor | Güzelburç, Vahit | |
dc.institutionauthor | Soytaş, Mustafa | |
dc.institutionauthor | Kiremit, Murat Can | |
dc.institutionauthor | Erkurt, Bülent | |
dc.institutionauthor | Altay, Bülent | |
dc.institutionauthor | Darçın, Kamil | |
dc.institutionauthor | Akbulut, Ziya | |
dc.institutionauthor | Albayrak, Selami | |
dc.identifier.trdizinid | TkRVd05URTRPQT09 | en_US |