Basit öğe kaydını göster

dc.contributor.authorÖrmeci, Tuğrul
dc.contributor.authorTekin, Bahar
dc.contributor.authorAltıntaş, Hilal Melis
dc.contributor.authorDurur Subaşı, Irmak
dc.contributor.authorÇaçan, Mehmet Akif
dc.date.accessioned2022-03-01T05:38:22Z
dc.date.available2022-03-01T05:38:22Z
dc.date.issued2022en_US
dc.identifier.citationÖrmeci, T., Tekin, B., Altıntaş, H. M., Durur Subaşı, I. ve Çaçan, M. A. (2022). Comparison of conventional MRI, MR arthrography, MR arthrography with traction, MR arthrography with pressure in the evaluation of articular distension. Journal of Orthopaedics, 30, 12-17. https://doi.org/10.1016/j.jor.2022.02.001en_US
dc.identifier.issn0972-978X
dc.identifier.urihttps://doi.org/10.1016/j.jor.2022.02.001
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9033
dc.description.abstractObjective: To evaluate the performance of conventional MRI, standard MR arthrography, MR arthrography with traction and MR arthrography with pressure in articular distension in patients with ACL injury. Design and patients: The consecutive patients (7 female, 21 male) with acute ACL injured conventional MRI, MR arthrography, MR arthrography with traction and MR arthrography with pressure were evaluated. Results: The amount of distension in the joint was evaluated in the posterior, femorotibial and anterior com- partments. Medially, between the meniscus posterior horn and the tibial corner, MRA with pressure was found to be more effective in showing this distance than MRA with traction (p < 0,05). Laterally, in measurements made between the posterior horn of the meniscus and the capsule, MRA with traction and MRA with pressure are more effective showing this distance than conventional MRI and standard MRA (p < 0,05). In measurements made medially, between the posterior horn of the meniscus and the capsule, MRA with traction is more effective in showing this distance than standard MRA (p < 0,05). In all three different MRA modalities, the lateral femo- rotibial joint distance was found to be statistically higher than conventional MRI (p < 0,05). Medial femorotibial joint distance was found to be statistically higher in MRA with pressure than in conventional MRI and standard MRA (p < 0,05). The medial infrapatellar distance was found to be statistically higher in MRA with pressure than standard MRA and MRA with traction (p < 0,05). The lateral infrapatellar distance is higher in MRA with pressure than in MRA with traction, and this height is statistically significant (p < 0,05). Conclusion: Traction and pressure applications added to MRA will increase the effectiveness of the method by increasing the distension in the knee joint. Although both seem to be effective in creating distension in posterior compartment and femorotibial joint distance, MRA with pressure is more effective especially in anterior compartment.en_US
dc.language.isoengen_US
dc.publisherReed Elsevier India Pvt. Ltd.en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectMR Arthrographyen_US
dc.subjectMR Arthrography With Tractionen_US
dc.subjectMR Arthrography With Pressureen_US
dc.subjectArticular Distensionen_US
dc.titleComparison of conventional MRI, MR arthrography, MR arthrography with traction, MR arthrography with pressure in the evaluation of articular distensionen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Orthopaedicsen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalıen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalıen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Temel Tıp Bilimleri Bölümü, Anatomi Ana Bilim Dalıen_US
dc.authorid0000-0001-8532-4917en_US
dc.authorid0000-0003-3122-4499en_US
dc.identifier.volume30en_US
dc.identifier.startpage12en_US
dc.identifier.endpage17en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.jor.2022.02.001en_US
dc.institutionauthorÖrmeci, Tuğrul
dc.institutionauthorTekin, Bahar
dc.institutionauthorAltıntaş, H. M.
dc.institutionauthorDurur Subaşı, Irmak
dc.institutionauthorÇaçan, Mehmet Akif
dc.identifier.wos000820170000003en_US
dc.identifier.scopus2-s2.0-85124322595en_US
dc.identifier.pmid35210720en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster