dc.contributor.author | Akgül, Sinem | |
dc.contributor.author | Gündoğdu, Ceyda | |
dc.contributor.author | Bala, Oya | |
dc.date.accessioned | 2022-02-03T06:48:19Z | |
dc.date.available | 2022-02-03T06:48:19Z | |
dc.date.issued | 2022 | en_US |
dc.identifier.citation | Akgül, S., Gündoğdu, C. ve Bala, O. (2022). Effects of storage time and restoration depth on instrumental color adjustment potential of universal resin composites. Journal of Oral Science, 64(1), 49-52. https://dx.doi.org/10.2334/josnusd.21-0290 | en_US |
dc.identifier.issn | 1343-4934 | |
dc.identifier.issn | 1880-4926 | |
dc.identifier.uri | https://dx.doi.org/10.2334/josnusd.21-0290 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12511/8953 | |
dc.description.abstract | Purpose: To determine the instrumental color adjustment potential (CAP-I) of 3 universal composites at 2 time intervals and 2 depths.
Methods: Omnichroma, Estelite Sigma Quick, and Filtek Universal Restorative were tested. Two types of specimens were prepared. For dual specimens, Class V restorations were created in anterior denture teeth and restored with resin composites. For single specimens, replications were fabricated with resin composites (n = 10). Unrestored teeth were used for comparison. Color was measured with a spectrophotometer at 24 h and 1 month, and CAP-I was calculated. Data were compared by analysis of variance followed by the Student t-test and paired sample t-test.
Results: The CAP-I of tested materials ranged from 0.11 to 0.27 at 24 h and from 0.60 to 0.76 at 1 month. At 24 h, Omnichroma yielded the highest values, followed by Estelite Sigma Quick and Filtek Universal Restorative (P < 0.05). CAP-I was significantly higher at 1 month than at 24 h in all groups. In all groups, restorations with a depth of 3.0 mm yielded better results than restorations with a depth of 2.0 mm (P < 0.05).
Conclusion: Storage time and restoration depth were positively associated with CAP-I. Single-shade and multi-shade universal composites are good alternatives for color-matched, esthetically satisfying restorations. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Nihon University | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Blending Effect | en_US |
dc.subject | Color Adjustment Potential | en_US |
dc.subject | Spectrophotometer | en_US |
dc.subject | Universal Resin Composite | en_US |
dc.title | Effects of storage time and restoration depth on instrumental color adjustment potential of universal resin composites | en_US |
dc.type | article | en_US |
dc.relation.ispartof | Journal of Oral Science | en_US |
dc.department | İstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Ana Bilim Dalı | en_US |
dc.identifier.volume | 64 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 49 | en_US |
dc.identifier.endpage | 52 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.2334/josnusd.21-0290 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.identifier.wos | 000746122400010 | en_US |
dc.identifier.scopus | 2-s2.0-85123812721 | en_US |
dc.identifier.pmid | 34911896 | en_US |
dc.identifier.scopusquality | Q3 | en_US |