Basit öğe kaydını göster

dc.contributor.authorAkgül, Sinem
dc.contributor.authorGündoğdu, Ceyda
dc.contributor.authorBala, Oya
dc.date.accessioned2022-02-03T06:48:19Z
dc.date.available2022-02-03T06:48:19Z
dc.date.issued2022en_US
dc.identifier.citationAkgül, S., Gündoğdu, C. ve Bala, O. (2022). Effects of storage time and restoration depth on instrumental color adjustment potential of universal resin composites. Journal of Oral Science, 64(1), 49-52. https://dx.doi.org/10.2334/josnusd.21-0290en_US
dc.identifier.issn1343-4934
dc.identifier.issn1880-4926
dc.identifier.urihttps://dx.doi.org/10.2334/josnusd.21-0290
dc.identifier.urihttps://hdl.handle.net/20.500.12511/8953
dc.description.abstractPurpose: To determine the instrumental color adjustment potential (CAP-I) of 3 universal composites at 2 time intervals and 2 depths. Methods: Omnichroma, Estelite Sigma Quick, and Filtek Universal Restorative were tested. Two types of specimens were prepared. For dual specimens, Class V restorations were created in anterior denture teeth and restored with resin composites. For single specimens, replications were fabricated with resin composites (n = 10). Unrestored teeth were used for comparison. Color was measured with a spectrophotometer at 24 h and 1 month, and CAP-I was calculated. Data were compared by analysis of variance followed by the Student t-test and paired sample t-test. Results: The CAP-I of tested materials ranged from 0.11 to 0.27 at 24 h and from 0.60 to 0.76 at 1 month. At 24 h, Omnichroma yielded the highest values, followed by Estelite Sigma Quick and Filtek Universal Restorative (P < 0.05). CAP-I was significantly higher at 1 month than at 24 h in all groups. In all groups, restorations with a depth of 3.0 mm yielded better results than restorations with a depth of 2.0 mm (P < 0.05). Conclusion: Storage time and restoration depth were positively associated with CAP-I. Single-shade and multi-shade universal composites are good alternatives for color-matched, esthetically satisfying restorations.en_US
dc.language.isoengen_US
dc.publisherNihon Universityen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBlending Effecten_US
dc.subjectColor Adjustment Potentialen_US
dc.subjectSpectrophotometeren_US
dc.subjectUniversal Resin Compositeen_US
dc.titleEffects of storage time and restoration depth on instrumental color adjustment potential of universal resin compositesen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Oral Scienceen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Ana Bilim Dalıen_US
dc.identifier.volume64en_US
dc.identifier.issue1en_US
dc.identifier.startpage49en_US
dc.identifier.endpage52en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.2334/josnusd.21-0290en_US
dc.identifier.wosqualityQ4en_US
dc.identifier.wos000746122400010en_US
dc.identifier.scopus2-s2.0-85123812721en_US
dc.identifier.pmid34911896en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster