Ara
Toplam kayıt 7, listelenen: 1-7
Cyclic fatigue resistance of 2Shape, twisted file and EndoSequence xpress nickel-titanium rotary files at intracanal temperature
(Tabriz University of Medical Sciences, Faculty of Dentistry, 2018)
Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape ...
Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files
(Wiley, 2018)
AimTo compare the cyclic fatigue resistance and bending properties of R-Pilot and WaveOne Gold (WOG) Glider files, at intracanal temperature (35 degrees C). MethodologyForty R-Pilot and 40 WOG Glider files were subjected ...
Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double (S-shaped) curvature
(Wiley, 2018)
AimTo examine the cyclic fatigue resistances of R-Pilot, HyFlex EDM and PathFile NiTi glide path files in S-shaped artificial canals. MethodologyTwenty R-Pilot (12.5/.04), 20 HyFlex EDM (10/.05) and 20 PathFile (19/.02) ...
Effect of glide path creating on cyclic fatigue resistance of reciproc and reciproc blue nickel-titanium files: A laboratory study
(Elsevier Science Inc, 2018)
Introduction: The purpose of this article was to compare the cyclic fatigue resistance of Reciproc and Reciproc Blue files (VDW GmbH, Munich, Germany) that were used to prepare root canals of mandibular molar teeth with ...
Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature
(Wiley, 2018)
AimTo compare the cyclic fatigue resistance of the One G, ProGlider, HyFlex EDM and R-Pilot glide path NiTi files at body temperature. MethodologyTwenty One G (size 14, .03 taper), 20 ProGlider (size 16, .02 taper), 20 ...
Apically extruded debris during root canal instrumentation with reciproc blue, hyflex edm, and xp-endo shaper nickel-titanium files
(Elsevier Science Inc, 2018)
Introduction: The purpose of this study was to investigate the amount of apically extruded debris by Reciproc Blue (REC Blue; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent, Altstatten, Switzerland), and XP-endo ...
Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals
(Springer, 2018)
The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, ...