Ara
Toplam kayıt 20, listelenen: 1-10
Cyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne gold, and twisted file adaptive rotary files under different temperatures and ambient conditions
(2019)
Background. This study examined the effects of changes in temperature and environmental conditions on the cyclic fatigue resistance of Reciproc Blue, HyFlex EDM, WaveOne Gold, and Twisted File Adaptive. Methods. Forty-five ...
FiberSite ve relyx fiber post sistemlerinin kök kanal dentinine push-out bağlantı dayanımlarının karşılaştırılması
(Türkiye Klinikleri Yayınevi, 2018)
Dual polimerize simanla yapıştırılmış FiberSite ve RelyX post sistemlerinin kök kanal dentinine bağlantı dayanımlarının karşılaştırılmasıdır. Gereç ve Yöntemler: Çalışmada 40 adet çe-- kilmiş tek köklü diş kullanıldı. ...
Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature
(Korean Academy of Conservative Dentistry, 2020)
Objectives: This study aims to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium (NiTi) rotary files at body temperature.Materials and methods: In total, 80 VDW.ROTATE ...
Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature
(Tabriz University of Medical Sciences, Faculty of Dentistry, 2020)
Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in double-curved canals in a simulated clinical ...
Cyclic fatigue resistance of 2Shape, twisted file and EndoSequence xpress nickel-titanium rotary files at intracanal temperature
(Tabriz University of Medical Sciences, Faculty of Dentistry, 2018)
Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape ...
Pull-out retentive resistance of fiber posts restored with different core materials
(Galenos Publishing, 2022)
Objective: This study aimed to assess the pull-out bonding resistance of FiberSite and RelyX Fiber posts constructed from core structures using various resin cement.
Materials and Methods: Sixty mandibular premolar teeth ...
Mechanical properties of the new generation RACE EVO and r-motion nickel-titanium instruments
(MDPI, 2022)
This study aimed to evaluate and compare the dynamic cyclic fatigue, torsional and bending resistance of two novel RACE EVO (FKG Dentaire SA, La Chaux de Fonds, Switzerland) and R-Motion (FKG) nickel-titanium instruments ...
Impact of COVID-19 pandemic on continuing professional development of endodontists: A comprehensive survey study
(Türkiye Klinikleri, 2022)
Objective: Continuing professional development (CPD) is a lifelong process that continues despite all kinds of obstacles. The aim of this study was to evaluate of endodontists’ attitudes towards CPD during the coronavirus ...
Influence of size and taper of basic root canal preparation on root canal cleanliness: A scanning electron microscopy study
(Wiley, 2019)
Aim To investigate whether a minimally invasive basic root canal preparation technique has an influence on root canal cleanliness in extracted mandibular molar teeth. Methodology A total of 80 root canals (40 mesiobuccal ...
Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files
(Wiley, 2018)
AimTo compare the cyclic fatigue resistance and bending properties of R-Pilot and WaveOne Gold (WOG) Glider files, at intracanal temperature (35 degrees C). MethodologyForty R-Pilot and 40 WOG Glider files were subjected ...