Ara
Toplam kayıt 7, listelenen: 1-7
Comparison of thermal stress on various restorative post and core materials generated by oral temperature changes using three dimensional finite element analysis
(2015)
Background and Aim: The purpose of this study was to compare thermal stress on various restorative post and core materials generated by oral temperature changes using three dimensional finite element analysis. Materials ...
Effect of liquid polishing materials on the stainability of bis-acryl interim restorative material in vitro
(Mosby, 2015)
Statement of problem. The discoloration of interim restorations may negatively affect a patient's perception of treatment. Purpose. The purpose of this study was to investigate the effect of liquid polishing materials on ...
Effects of various denture cleansers on surface roughness of hard permanent reline resins
(Japanese Society for Dental Materials and Devices, 2015)
The aim of this study was to investigate the influence of denture cleansers on surface roughness (Ha, mu m) of two hard permanent reline resins and a conventional acrylic denture base resin. Fifty specimens of each material, ...
Zirconia-based crowns up to 5 years in function: A retrospective clinical study and evaluation of prosthetic restorations and failures
(Quintessence Publishing, 2015)
Purpose: The purpose of this retrospective study was to evaluate the 5-year clinical performance and failure rate of single- or multiple-unit zirconia-based crowns. Materials and Methods: A total of 148 patients (39 men ...
Effect of opaque layer application on the color of resin composites used to fill access openings of screw-retained implant restorations
(Quintessence Publishing, 2015)
The purpose of this preliminary in vitro study was to evaluate the effect of an opaque layer and application of resin composite in dual colors on the Delta E values of resin composites used to fill access openings of ...
Assessment of hygiene habits and attitudes among removable partial denture wearers in a university hospital
(Medknow Publications, 2015)
Aims: The aim of this study was conducting a survey of hygiene habits and use of removable partial dentures (RPDs) and correlate them with the social conditions of the interviewees. Methods: A total of 145 RPD wearers were ...
Is it safe to reuse dental implant healing abutments sterilized and serviced by dealers of dental implant manufacturers? An in vitro sterility analysis
(Lippincott Williams and Wilkins, 2015)
Purpose: This study was undertaken to investigate the sterility of used healing abutments sterilized and serviced by dealers of dental implant manufacturers. Materials and Methods: Sixty used but sterilized healing abutments ...