Ara
Toplam kayıt 37, listelenen: 11-20
Mechanical properties of the new generation RACE EVO and r-motion nickel-titanium instruments
(MDPI, 2022)
This study aimed to evaluate and compare the dynamic cyclic fatigue, torsional and bending resistance of two novel RACE EVO (FKG Dentaire SA, La Chaux de Fonds, Switzerland) and R-Motion (FKG) nickel-titanium instruments ...
Impact of COVID-19 pandemic on continuing professional development of endodontists: A comprehensive survey study
(Türkiye Klinikleri, 2022)
Objective: Continuing professional development (CPD) is a lifelong process that continues despite all kinds of obstacles. The aim of this study was to evaluate of endodontists’ attitudes towards CPD during the coronavirus ...
Influence of size and taper of basic root canal preparation on root canal cleanliness: A scanning electron microscopy study
(Wiley, 2019)
Aim To investigate whether a minimally invasive basic root canal preparation technique has an influence on root canal cleanliness in extracted mandibular molar teeth. Methodology A total of 80 root canals (40 mesiobuccal ...
Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files
(Wiley, 2018)
AimTo compare the cyclic fatigue resistance and bending properties of R-Pilot and WaveOne Gold (WOG) Glider files, at intracanal temperature (35 degrees C). MethodologyForty R-Pilot and 40 WOG Glider files were subjected ...
Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double (S-shaped) curvature
(Wiley, 2018)
AimTo examine the cyclic fatigue resistances of R-Pilot, HyFlex EDM and PathFile NiTi glide path files in S-shaped artificial canals. MethodologyTwenty R-Pilot (12.5/.04), 20 HyFlex EDM (10/.05) and 20 PathFile (19/.02) ...
Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne gold, and reciproc blue nickel-titanium instruments
(Elsevier Science Inc, 2017)
Introduction: The purpose of this study was to compare the cyclic fatigue resistances of Reciproc Blue (VDW, Munich, Germany), HyFlex EDM (Coltene/Whaledent, Altstitten, Switzerland), WaveOne Gold (Dentsply Maillefer, ...
Effect of glide path creating on cyclic fatigue resistance of reciproc and reciproc blue nickel-titanium files: A laboratory study
(Elsevier Science Inc, 2018)
Introduction: The purpose of this article was to compare the cyclic fatigue resistance of Reciproc and Reciproc Blue files (VDW GmbH, Munich, Germany) that were used to prepare root canals of mandibular molar teeth with ...
Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature
(Wiley, 2018)
AimTo compare the cyclic fatigue resistance of the One G, ProGlider, HyFlex EDM and R-Pilot glide path NiTi files at body temperature. MethodologyTwenty One G (size 14, .03 taper), 20 ProGlider (size 16, .02 taper), 20 ...
Apically extruded debris during root canal instrumentation with reciproc blue, hyflex edm, and xp-endo shaper nickel-titanium files
(Elsevier Science Inc, 2018)
Introduction: The purpose of this study was to investigate the amount of apically extruded debris by Reciproc Blue (REC Blue; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent, Altstatten, Switzerland), and XP-endo ...
Dental enumeration and multiple treatment detection on panoramic X-rays using deep learning
(Nature Research, 2021)
In this paper, a new powerful deep learning framework, named as DENTECT, is developed in order to instantly detect five different dental treatment approaches and simultaneously number the dentition based on the FDI notation ...