Ara
Toplam kayıt 5, listelenen: 1-5
Biomechanical study on three screw-based atlantoaxial fixation techniques: A finite element study
(Korean Society of Spine Surgery, 2022)
Study Design: This is a finite element study. Purpose: This study is aimed to compare the biomechanical behaviors of three screw-based atlantoaxial fixation techniques. Overview of Literature: Screw-based constructs that ...
Lumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: A retrospective clinical and radiological analysis of 71 patients
(Korean Orthopaedic Association, 2017)
Background: This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. Methods: A total of 71 patients underwent single-level ...
Influence of three-dimensional reconstruction method for building a model of the cervical spine on its biomechanical responses: A finite element analysis study
(Hindawi Publishing Corporation, 2016)
In some finite element analysis studies of models of sections of the spine, the three-dimensional solid model is built by assuming symmetry about the mid-sagittal plane of the section, whereas in other studies, the model ...
Complications of 2-level dynamic stabilization: A correlative clinical and radiological analysis at two-year follow-up on 103 patients
(Turkish Neurosurgical Society, 2018)
AIM: To investigate the postoperative complications, such as screw loosening, screw breakage and adjacent segment disease (ASD), in patients who underwent surgery with 2-level dynamic stabilization systems. MATERIAL and ...
How to reduce stress on the pedicle screws in thoracic spine? Importance of screw trajectory: A finite element analysis
(Turkish Neurosurgical Society, 2019)
AIM: To investigate the biomechanical comparison of thoracic transpedicular screw trajectories on the sagittal plane. MATERIAL and METHODS: A three-dimensional, non-linear finite element analysis (FEA) model of T8 through ...