Basit öğe kaydını göster

dc.contributor.authorYücel, Burak
dc.contributor.authorGedikbaşı, Ali
dc.contributor.authorDündar, Öznur
dc.contributor.authorOlgaç, Yusuf
dc.contributor.authorYıldırım, Doǧukan
dc.contributor.authorYıldırım, Gökhan Yetkin
dc.contributor.authorPolat, İbrahim
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T20:02:39Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T20:02:39Z
dc.date.issued2016en_US
dc.identifier.citationYücel, B., Gedikbaşı, A., Dündar, Ö., Olgaç, Y., Yıldırım, D., Yıldırım, G. Y. ve Polat, İ. (2016). The utility of first trimester uterine artery Doppler, placental volume and PAPP-A levels alone and in combination to predict preeclampsia. Pregnancy Hypertension-An International Journal Of Womens Cardiovascular Health, 6(4), 269-273. https://dx.doi.org/10.1016/j.preghy.2016.04.007en_US
dc.identifier.issn2210-7789
dc.identifier.urihttps://dx.doi.org/10.1016/j.preghy.2016.04.007
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3700
dc.descriptionWOS: 000390825400006en_US
dc.descriptionPubMed ID: 27939466en_US
dc.description.abstractIn this study, we aimed to evaluate the detection of pre-eclampsia (PE) by integrating uterine artery Doppler, placental volume, and pregnancy-associated plasma protein A (PAPP-A) levels in the first trimester. We prospectively recruited 602 women that underwent 11-13 weeks' aneuploidy screening. The mean pulsatility index (PI) of the uterine arteries and the placental volume were measured by ultrasonography. Measurement of PAPP-A levels has been performed at the same day' of ultrasonographic examinations. The 90th percentile of uterine artery PI and the 10th percentile of placental volume and PAPP-A levels were used as cut-offs. Uterine artery PI, placental volume, and PAPP-A levels had similar sensitivities in predicting PE (53.66%, 63.41%, and 70.73%, respectively). Use of the parameters in combination had better sensitivity. If one parameter was positive, the sensitivity was 92.68% with 85.20% specificity. If at least two parameters were positive, the sensitivity was 85.37% with 98.89% specificity. In conclusion, the combination of increased PI of uterine artery with low placental volume and low PAPP-A levels in the first trimester achieved better results than either test alone in the prediction of PE.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPregnancy-Associated Plasma Protein A (PAPP-A)en_US
dc.subjectPlacental Volumeen_US
dc.subjectPredict Preeclampsiaen_US
dc.titleThe utility of first trimester uterine artery Doppler, placental volume and PAPP-A levels alone and in combination to predict preeclampsiaen_US
dc.typearticleen_US
dc.relation.ispartofPregnancy Hypertension-An International Journal Of Womens Cardiovascular Healthen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Kadın Hastalıkları ve Doğum Ana Bilim Dalıen_US
dc.identifier.volume6en_US
dc.identifier.issue4en_US
dc.identifier.startpage269en_US
dc.identifier.endpage273en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.preghy.2016.04.007en_US
dc.identifier.wosqualityQ2en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster