Ara
Toplam kayıt 9, listelenen: 1-9
Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature
(Korean Academy of Conservative Dentistry, 2020)
Objectives: This study aims to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium (NiTi) rotary files at body temperature.Materials and methods: In total, 80 VDW.ROTATE ...
Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature
(Tabriz University of Medical Sciences, Faculty of Dentistry, 2020)
Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in double-curved canals in a simulated clinical ...
Influence of size and taper of basic root canal preparation on root canal cleanliness: A scanning electron microscopy study
(Wiley, 2019)
Aim To investigate whether a minimally invasive basic root canal preparation technique has an influence on root canal cleanliness in extracted mandibular molar teeth. Methodology A total of 80 root canals (40 mesiobuccal ...
Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files
(Wiley, 2018)
AimTo compare the cyclic fatigue resistance and bending properties of R-Pilot and WaveOne Gold (WOG) Glider files, at intracanal temperature (35 degrees C). MethodologyForty R-Pilot and 40 WOG Glider files were subjected ...
Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature
(Wiley, 2018)
AimTo compare the cyclic fatigue resistance of the One G, ProGlider, HyFlex EDM and R-Pilot glide path NiTi files at body temperature. MethodologyTwenty One G (size 14, .03 taper), 20 ProGlider (size 16, .02 taper), 20 ...
Apically extruded debris during root canal instrumentation with reciproc blue, hyflex edm, and xp-endo shaper nickel-titanium files
(Elsevier Science Inc, 2018)
Introduction: The purpose of this study was to investigate the amount of apically extruded debris by Reciproc Blue (REC Blue; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent, Altstatten, Switzerland), and XP-endo ...
Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel-titanium rotary instrument
(Springer, 2019)
The aim of the present study was to evaluate the effect of environmental temperature, heat-treatment*** and design on the cyclic fatigue resistance of OneShape (OS), OneShape new generation (OSNG) and One Curve (OC) NiTi ...
Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals
(Springer, 2018)
The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, ...
Efficacy of different irrigant activation devices in removing dentin debris from an artificial isthmus connecting curved canals
(John Wiley and Sons Inc, 2023)
The aim of this study was to evaluate the debridement efficacy of sonic irrigation (EDDY; VDW, Munich, Germany and EndoActivator; Dentsply-Sirona, Ballaigues, Switzerland) and ultrasonically activated irrigation (Irrisafe; ...