Ara
Toplam kayıt 3, listelenen: 1-3
Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature
(Tabriz University of Medical Sciences, Faculty of Dentistry, 2020)
Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in double-curved canals in a simulated clinical ...
Cyclic fatigue resistance of 2Shape, twisted file and EndoSequence xpress nickel-titanium rotary files at intracanal temperature
(Tabriz University of Medical Sciences, Faculty of Dentistry, 2018)
Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape ...
Mechanical properties of the new generation RACE EVO and r-motion nickel-titanium instruments
(MDPI, 2022)
This study aimed to evaluate and compare the dynamic cyclic fatigue, torsional and bending resistance of two novel RACE EVO (FKG Dentaire SA, La Chaux de Fonds, Switzerland) and R-Motion (FKG) nickel-titanium instruments ...