Ara
Toplam kayıt 22, listelenen: 1-10
Safety and efficacy outcomes of bioresorbable scaffolds in long segment coronary lesions
(Sağlık Bilimleri Üniversitesi, Kartal Koşuyolu Yüksek İhtisas Eğitim ve Araştırma Hastanesi, 2018)
Introduction: There is limited knowledge about the use of bioresorbable scaffolds (BRSs) in long segment coronary artery lesions. We aimed to evaluate the clinical outcomes of BRS-BRS and drug eluting stents (DESs)-BRS ...
Outcomes of the novolimus-eluting bioresorbable vascular scaffold in real world clinical practice
(Edizioni Minerva Medica, 2021)
BACKGROUND: Most of the current data regarding the use of bioresorbable scaffolds (BRS) come from everolimus-eluting stent platforms. Adverse events with the everolimus-eluting BRSs which are the most comprehensively ...
Impact of aortic stiffness on the frequency of paroxysmal atrial fibrillation recurrences
(Taylor & Francis, 2015)
Background The relationship between arterial stiff ness (AS) and atrial fi brillation (AF) incidence is well-known. In this study we aimed to investigate the relationship between AS parameters and AF occurence as well as ...
Value of renal vascular doppler sonography in cardiorenal syndrome type 1
(Wiley, 2021)
Objectives Worsening of renal function in a patient with acute decompensated heart failure is called cardiorenal syndrome (CRS) type 1. Recent studies have shown an association of persistent systemic venous congestion with ...
Predicting ventricular arrhythmias in cardiac resynchronization therapy: The impact of persistent electrical dyssynchrony
(Wiley, 2016)
BackgroundAlthough response to cardiac resynchronization therapy (CRT) has been conventionally assessed with left ventricular volume reduction, ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation ...
Pocket haematoma after cardiac electronic device implantation in patients receiving antiplatelet and anticoagulant treatment: A single-centre experience
(Taylor and Francis, 2017)
Objective In modern cardiology practice, implantation of cardiac electronic devices in patients taking anticoagulant or antiplatelet therapy is a common clinical scenario. Bleeding complications are of particular concern ...
Changes in electrocardiographic p wave parameters after cryoballoon ablation and their association with atrial fibrillation recurrence
(Wiley-Blackwell, 2016)
Background: Changes in P wave parameters after circumferential pulmonary vein isolation (CPVI) have been previously identified. In this study, we aimed to determine the changes in P wave parameters surface electrocardiogram ...
Failed transcatheter mitral valve-in-ring implantation followed by transapical valve-in-valve within the ring and ad hoc paravalvular leak closure
(Turkish Society of Cardiology, 2021)
There is a rapid emergence of transcatheter mitral valve-invalve (TMVIV) and valve-in-ring (TMVIR) techniques as an alternative to the conventional surgical valve replacement in ineligible patients requiring repeat surgery ...
Real-life data regarding acute procedural success and 1-year clinical outcome of desolve bioresorbable scaffolds
(Wiley, 2017)
Objectives: We aimed to evaluate the peri-procedural success of DESolve bio-resorbable scaffolds (BRSs) and analyzed real-life data about major cardiac events during 1-year follow-up. Background: There is little information ...
Effect of QRS narrowing after cardiac resynchronization therapy on functional mitral regurgitation in patients with systolic heart failure
(Elsevier Inc., 2016)
The determinants of improvement in functional mitral regurgitation (FMR) after cardiac resynchronization therapy (CRT) remain unclear. We evaluated the predictors of FMR improvement and hypothesized that CRT-induced change ...